13.4 HOW TO SET THE REGENERATION MODE (reserved to Technical Assistance Service)
From the programming display no. 3, move the selection to the parameter “Regeneration” with keys
.
- Press key
to confirm the selection, the display below will be shown
Choose with keys
the desired regeneration mode:
• VOLUME/ TIME
• pure VOLUME
• VOLUME with time
• TIME
- Press key
to confirm settings.
P.S. For potable use, it is recommended to regenerate max. every 4 days, therefore the regeneration mode
needs to be set at volume/ time or at time.
13.4.1 REGENERATION BY VOLUME/TIME (reserved to Technical Assistance Service)
The display below will be shown
- press keys
to change the regeneration frequency;
Set a value included between 1 and 19 days.
- Press key
to come back to the previous selection, or
- Press key
to confirm settings, the display below will be shown
- press keys
to change the regeneration time;
- press key
to come back to the previous selection, or
- press key
to confirm settings.
REGENERATION MODE
MODE VOLUME/ TIME
TO CHANGE PRESS
+
or –
TO CONFIRM PRESS B
REGENERATION FREQ.
Days (1-19 ) 4
TO CHANGE PRESS
+
or –
TO CONFIRM PRESS B
6
7
REGENERATION TIME
Regeneration Hour 2
TO CHANGE PRESS
+
or –
TO CONFIRM PRESS B
8