Programming will automatically close and the main display no. 2 is restored.
The softener will work by volume/time, with priority to volume. This means that if the water volume that
can be softened is used before the day programmed for regeneration, this will occur in advance, but will
respect the set time anyway.
P.S. For potable use, it is recommended to regenerate max. every 4 days.
13.4.2 REGENERATION BY PURE VOLUME
From the display no. 6, select the mode Pure Volume by pressing keys ;
- by pressing key
programming will automatically close and the display below will be shown
The softener will work by pure volume. This means that regeneration will be carried out as soon as the
water volume that can be softened is reached.
13.4.3 REGENERATION BY VOLUME WITH TIME
From the display no. 6, select the mode Volume by pressing keys
;
- by pressing
, the display below will be shown
- press key
to change the regeneration time;
- press key
to come back to the previous selection, or
- press key
to confirm settings
Programming will automatically close.
The softener will work by volume with time. This means that, when the water volume is reached, the
regeneration will take place at the time set.
13.4.4 REGENERATION BY TIME
The display below will be shown
- press keys
to change the regeneration frequency;
REGENERATION TIME
REG. VOLUME h 02
TO CHANGE PRESS
+
or –
TO CONFIRM PRESS B
REGENERATION FREQ.
Days (1-19 ) 4
TO CHANGE PRESS
+
or –
TO CONFIRM PRESS B
10
Clock 17:20
REG. VOLUME H ??
IN 50° F OUT 15°F