13.5 HOW TO SET IN-OUT HARDNESS (reserved to Technical Assistance Service)
From the programming display no. 3, move the selection to the parameter “Hardness” with the key
- Press key
to confirm the selection, the display below will be shown
- press keys
to change hardness at the entry (from 2 °f to 99 °f);
- press key
to confirm settings
the display below will be shown
- press keys
to change the hardness at the outlet (from 0 °f to 99 °f);
- press key
to come back to the previous selection, or
- press key
to confirm settings
Programming will automatically close and the main display is restored.
P.S. The programming of the water hardness value at the outlet is to be set only if the automatic by-pass
is installed.
For potable use a minimum hardness of 15 °f is recommended.
13.6 HOW TO SET PRESSURE AT THE ENTRY OF THE SOFTENER
(reserved to Technical Assistance Service)
From the programming display 3, move the selection on the parameter “Pressure” with the keys
- press key
to confirm the selection, the display below will be shown
- press keys
to change pressure (between 2 and 6 bar)
- press key
to confirm settings
WATER HARDNESS
HARDNESS 25 °f
TO CHANGE PRESS
+
or –
TO CONFIRM PRESS B
WATER HARDNESS
HARDNESS 15 °f
TO CHANGE PRESS
+
or –
TO CONFIRM PRESS B
PRESSURE
BAR 2
TO CHANGE PRESS
+
or –
TO CONFIRM PRESS B