80
13.14 - WATER SENTINEL PRO - STATUS OF THE MICRO-LEAKAGE = ON
(reserved to Technical Assistance Service)
- Press key
to come back to the previous display, or
- press key
to confirm the setting.
the display below will be shown
- press keys to change the duration of the micro-leakage reading test (from 5 to 120
seconds; default value = 20 seconds).
Starting from the closing of the last tap open, the system Water Sentinel Pro carries out
every 2 hours a duration test lasting for the time set. The test is repeated three times
and in case of micro-leakages the message “MICRO-LEAKAGE ALARM” is displayed.
- Press key to come back to the previous display, or
- press key
to confirm the setting.
Programming will automatically close and the main display is restored.
13.15 HOW TO CHECK THE STATUS OF REGENERATIONS (reserved to Technical Assistance Service)
The ELECTRONIC TIMER VT 2000 allows to display the data about the regenerations to be carried out
and already carried out:
- from the main display
Press key and the display below will be shown
MICRO-LEAKAGE
TEST DURATION = 10 Sec
TO CHANGE PRESS
+
or –
TO CONFIRM PRESS B
26
27
1
➔ITALIANO -ENGLISH
-FRANCAIS -DEUTSCH
-ESPANOL
To Confirm Press
NEXT REGEN. (Days) DAYS: 4
last regen. (Days) DAYS: 0
REGENERATIONS 00001
NEXT PUSH B
1)
2)
3)