EasyManua.ls Logo

Geller SX-585 - Z Report Readings; Z1 and Z2 End-of-day;Weekly Readings

Geller SX-585
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
the “X2” Position and pressing the
Z1 Position and Z2 Position
There are two types of reports that can be taken in the "Z" position
"Z1"- Commonly known as an "end-of-day" reading. This prints transaction data and
resets all transaction totals to zero except the non-resettable ground total (NRGT).
The machine will, however, still accumulate totals in memory until a "Z2" report is
taken. TheZ1” Report can be taken by turning the Key to the “Z1” Position and
pressing
"Z2" - Commonly known as a "weekly" or "monthly" reading. This prints transaction
data either on a weekly or monthly basis and resets all transaction totals to zero
except the Non-resettable ground total (NRGT). The “Z2” Report can be taken
simply by turning the Key to the “Z2” Position and pressing
NOTE: If you do not have a pre-programmed Full Report button on your Keyboard
then this report can also be taken by turning the Key to the relevant reporting
position and pressing the Enter Key 3 times.
X 3
FULL
RPT
ENTER
FULL
RPT
FULL
RPT
Depending on your setup this maybe labeled
differently. Please see Page 13 for the report
key positions

Related product manuals