16 Operation
16.2.3.2.1.3 Changing the control parameters (Proc P, Proc I, Proc D and Proc T)
SetFunction
3
ProcCtrlMode: OFF
ON...OFF
r0w3
ProcCtrl
Nur verfügbar bei Proc CtrlMode: ON
Proc-P: 0.50
0.1...100.0
Proc-I: 2,0 s
0,1...999,9 s
Proc-D: 0.0
0.0...100.0
Proc-T: 1000 ms
1...10000 ms
r0w3
r0w3
r0w3
r0w3
Service
1
Mode
AUTO
A: w XX.X: x XX.X
SETUP
Mode
Man
M: w XX.X: x XX.X
Mode
OFF
Automatikbetrieb
manueller Betrieb
r0w0
r0w3
SetBasics
2
automatic operation
manual operation
Only available when ProcCtrlMode: ON
16.2.3.3 Access authorization in the configuration menu
In order to hinder unwanted changes to the parameter values, the configuration level of the product is secured with three differ-
ent access codes.
The factory code setting is as follows:
Code 1: Password 0 → (New Code: 1)
Code 2: Password 0 → (New Code: 2)
Code 3: Password 0 → (New Code: 3)
After entering the factory codes, these codes can be changed by the operator at any time.
The access priorities needed are marked in the configuration menu.
The way in which access codes can be changed is described under "Activation or deactivation of user access". (see “Activating/
deactivating user access“, page51)