www.gemu-group.com46 / 76GEMÜ 1436 cPos
16 Operation
Menu levels Submenu Display Function Value range Default setting
In 2 Determines the function
of the digital input "In 2"
OFF / ON OFF
Safe / ON
ParmSetB0
ParmSetB1
Poti / Ix
Digital output Submenu for setting the digital outputs
K1 Switch Defines the type of
output
NC / NO NO
K1 Fn Determines the function
of output K1
no no
P min
P max
P min/max
W min
W max
W min/max
X min
X max
X min/max
SSE min
SSE max
SSE min/max
Active
Error
Warning
AlarmMaxK1 Switch point that
switches after K1 is ex-
ceeded
0.2 ... 99.8 % 10.0 %
AlarmMinK1 Switch point that
switches after K1 is un-
dershot
0.2 ... 99.8 % 90.0 %
SSE1Time Delay time between error
detection and error mes-
sage to K1
0.1 to 100.0 s 5.0 s
K2 Switch Defines the type of
output
NC / NO NO
K2 Fn Determines the function
of output K2
no no
P min
P max
P min/max
W min
W max
W min/max
X min
X max
X min/max
SSE min
SSE max
SSE min/max