PH Auto: Measuring the pH dosing pump according to the supplied pH meter and adjusting
the stopping value according to the measurement.
PH SET: The menu for making the pH settings of the pool water is from the PH SET
submenu on the PH SETTINGS menu.
PH SET: After pressing the OK button on the PH SET submenu, the desired pH value is
reached with the arrows and the adjustment is made by pressing the OK button again. The
factory setting is 7.00 and the recommendation value is 7.20.
PH TOL. : The level of the pool water pH value is used to adjust the operation of the dosing
pump after the value set in this menu is reached.
For example, in a salt chlorine generator set to PH SET value 7.0, if the pH TOL value is set
to 00,10, the salt chlorine generator will run when the pH dosing pump reaches pH 7,10.
This tolerance value is set using the arrow keys and the OK key.
PH BUF.SEC : This menu selects whether the dosing pump is connected to a pH-increaser
or pH-reducer chemistry. In this case, the pH-increasing chemistry-dependent dosing
pump is prevented from further increasing the already high pH.
ATTENTION : IT’S IMPORTANT THAT THE CHEMICAL AND THE SELECTION OF THE
DOSAGE PUMP.
IF THE PH REDUCER IS CONNECTED, THE ABOVE OPTION SHOULD BE SELECTED. IF THE PH
INCREASER OS CONNECTED, THE OPTION TO BE (+) IS A SUBMITTED (-) SIGN (+)
SELECTED.
PH CALIBRATION: For the pH calibration, press the OK key in this option and then proceed
as follows.