3/4
To carry out the operation successfully, make sure the required electrical connections (bonnet switch and ignition) are properly connected.
If there is no bonnet switch, ground the GREEN wire (20-pin connector, pos. 15).
4.1 LEARNING NEW DEVICES
Storing memory is for 60 devices.
If an extra device is added, it automatically deletes the first device stored in memory.
To activate the code-learning mode proceed as follows:
With the system disarmed, open the vehicle bonnet and keep it opened or ground the GREEN wire.
The “ON-OFF” cycles must be carried out within 4 sec. otherwise the procedure is invalidated.
Cycle ignition key “ON-OFF”-“ON-OFF”-“ON-OFF”-“ON”.
At the 4th cycle leave ignition key “ON”.
A quick high-pitched chirp, a long low-pitched chirp and 2 flashes of the turn indicators will confirm the system is in learn mode. The LED will turn ON
steady.
Do not close the bonnet otherwise all previously programmed devices will be erased as described in the next paragraph.
The system is ready to receive the device codes.
1. Depending on which device is to be paired:
Press twice one of the buttons on the remote control;
Make the magnetic contact transmit twice (bring contact and magnet together and then move apart);
Press the opening detector button twice.
2. A short acoustic signal will then confirm the device has been learned.
3. Repeat this same procedure to learn other devices.
6. Turn ignition key “OFF”.
7. A long low-pitched chirp and a flash of the turn indicators will confirm the end of the procedure. The status LED will turn OFF.
8. Close the bonnet or remove the GREEN wire from ground (bonnet switch).
4.2 DELETING PROGRAMMED DEVICES
To clear the unit memory proceed as follows:
With the system disarmed, open the vehicle bonnet and keep it opened or ground the GREEN wire.
The “ON-OFF” cycles must be carried out within 4 sec. otherwise the procedure is invalidated.
Cycle ignition key “ON-OFF”-“ON-OFF”-“ON-OFF”-“ON”.
At the 4th cycle leave ignition key “ON”.
A high-pitched chirp, a low-pitched chirp and 2 flashes of the turn indicators will confirm the system is in delete mode. The LED will turn ON
steady.
Close the bonnet or remove the GREEN wire from ground (bonnet switch).
To clear the memory, leave the bonnet closed for at least 8 seconds.
If the bonnet is opened before 8 seconds, the devices will not be deleted.
The LED will switch OFF when the devices have been deleted.
Turn ignition key “OFF”.
A long low-pitched chirp and a flash of the turn indicators will confirm the end of the procedure.
4.0 - LEARNING & DELETING DEVICES

Other manuals for Gemini 933MHW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemini 933MHW and is the answer not in the manual?

Gemini 933MHW Specifications

General IconGeneral
BrandGemini
Model933MHW
CategorySecurity System
LanguageEnglish

Related product manuals