Gemini GEM-P801 Specifications

General IconGeneral
BrandGemini
ModelGEM-P801
CategorySecurity System
LanguageEnglish

Summary

Specifications

Current & Voltage Ratings

Electrical specifications including voltage, current limits, and output ratings.

Loop Characteristics

Details on loop voltage, current, and resistance for the panel zones.

Device Specifications

Information on keypad limits, receiver capacity, and wire length.

Transformer and Battery

Requirements for power transformer and battery backup.

Miscellaneous Specs

Physical dimensions, shipping weight, and operating temperature.

Product Information

UL Compatible Smoke Detectors

List of smoke detectors approved by UL for use with the GEM-P801.

Listings and Approvals

Compliance with UL, CSFM, and FCC standards.

Ordering Information

Part numbers for the panel, keypads, and accessories.

Panel Programming and Downloading

Defaulting the Panel

Steps to reset the panel to factory default settings.

Keypad Programming

Reference to instructions for programming via keypad.

Downloading Methods

Overview of local and remote downloading capabilities.

Installation Procedures

Mounting the Panel and Keypad

Guidelines for physically installing the control panel and keypads.

Wiring and Connections

Instructions for grounding, power, and telephone line connections.

Typical Fire Installation

Recommendations for installing smoke detectors and heat detectors.

Wiring and Operation Details

Zone Wiring

Procedures for wiring burglary and fire zones with EOL resistors.

PGM and Keypad Wiring

Details on PGM output wiring and keypad connections.

Keypad Operation and Sounder

Explains keypad LEDs, sounder feedback, and basic operation.

System Operation and Control

Keypad LEDs and Status Indicators

Meanings of various LEDs on the keypad.

Arming and Disarming the System

Procedures for arming, disarming, and using instant mode.

System Operation and Bypass Modes

Disarming, Alarm Memory, and Bypassing

Managing alarms, bypassing zones, and automatic bypass functions.

User Program Mode

Entering and using the user programming mode.

User Commands and Programming

User Mode Programming Example

Example of programming user codes.

GEM-P801 User Commands

List of commands for panel functions like Bell Test, Chime, etc.

Advanced Features and Troubleshooting

Optional User and Dealer Commands

Accessing PGM output and performing downloads.

Wireless Signal Strength Monitoring

Checking and logging wireless transmitter signal strength.

Zone Configuration and Data Logging

Uploading Signal Strength Data

Retrieving stored signal strength information.

Zone Feature Definitions

Explains various zone types like Exit/Entry, Home/Away, etc.

System Configuration Parameters

Zone Programming Options

Details on disabling EOL resistors and output settings.

System Time and Timer Settings

Configuring exit/entry delays, test timers, and supervisory timers.

System Feature Configuration

Keypad Feature Settings

Configuring keypad functions, panics, and displays.

Miscellaneous and Programmable Outputs

Settings for abort delay, easy exit, swinger shutdown, and PGM activation.

Output and Communication Configuration

Programmable Output Features

Assigning PGM outputs for various alarm and system events.

Telephone 1 Configuration

Programming subscriber ID, phone number, and receiver format.

Communication and Reporting Setup

Telco 1 Reporting Options

Defining zone and system reports for the primary phone line.

Backup Telephone Configuration

Setting up the secondary phone line for reporting.

Communicator and Pager Settings

Dialing Prefix and Communicator Features

Configuring dialing prefixes and communicator modes.

Pager Programming

Setting up pager formats, leading/trailing digits, and options.

Reporting Codes and Enhanced Features

Telephone 3 Programming

Configuration for a third telephone number.

Report Code Definitions

Explains zone, system, and event report codes.

Wireless System and Keyfob Configuration

Wireless Transmitter Mapping and Keyfob Setup

Mapping wireless devices and configuring keyfob functions.

Keyfob Auxiliary Function Programming

Assigning functions like Panic, AUX, or Bell ON to keyfob buttons.

Wireless Devices and Downloading

Keyfob Functions and Smoke Detectors

Configuring keyfob operations and wireless smoke detector supervision.

Downloading Procedures

Settings for callback numbers, ring counts, and download features.

Advanced Setup and Dealer Programming

Site Initiated Auto Downloading

Steps for automated downloads via PC-Preset.

Dealer Programming Options

Setting dealer code, user lockout, and system options.

System Defaults and Redial Settings

Programming Block Notes

Notes regarding programming blocks [96] and [97] on panel default.

Number of Re-Dials Configuration

Setting the number of re-dial attempts for communication failures.

System Troubleshooting and Reporting

Viewing System Troubles

Method to access and interpret system trouble codes.

System Trouble Reporting Codes

Pulse and Point ID codes for various system troubles.

System Trouble Details

System Trouble Conditions and Causes

Detailed table of system troubles, their causes, and actions.

Troubleshooting Common Issues

Bell Output and Supervision Problems

Addresses issues with bell output voltage, supervision, and short circuits.

Keypad Sounder and Chime Configuration

How to remove keypad sounder on alarm and activate zone chime.

PGM Output and Internal Circuitry

Information on PGM output pulsing and internal over-current protection.

Troubleshooting Specific Components

Keypad Sounder and Chime Control

Disabling keypad sounder for entry time and chime.

Transmitter and Keypad LED Issues

Diagnosing transmitter response and keypad LED flicker.

Wiring Diagram and Notes

GEM-P801 Wiring Diagram

Visual guide for connecting system components.

Wiring Diagram Notes

Important notes regarding wiring practices and component compatibility.

Warranty and Regulatory Information

NAPCO Limited Warranty Details

Terms and conditions of the product warranty.

FCC Compliance Statement

Required FCC statement regarding radio frequency energy and interference.