Gemini GEM-P801 - Advanced Setup and Dealer Programming; Site Initiated Auto Downloading; Dealer Programming Options

Gemini GEM-P801
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
The requirements for Site Initiated Auto
Downloading are as follows:
1. Download Computer running PCPreset.
2. Program the telephone number of the
Download Computer in location [90]
Callback Telephone Number.
3. Program location [93] with the number of
the PCPreset account that is to be
downloaded.
PCPreset
1. Create the GEM-P801 account to be
downloaded using PCD-Windows
Quickloader Software.
1. Create a List using PCPreset.
2. Select the account by pressing
t
.
Select the desired account from the list of
PCD3000 accounts available. (The
location in the list is the Auto Download
ID Number [93])
3. Tag the list by entering
aD
(
download)
4. Enter Standby Mode by entering
o
.
The Computer is now in STANDBY
Site
At the site perform the following three steps:
1. Arm the panel.
2. Disarm the panel.
3. Enter
A6
. The panel will now
call the download computer running
PCPreset. PCPreset will answer the call,
establish a connection, and then
download the account that matches the
Auto Download ID Number [93] with the
account of the same number in the list
that PCPreset is currently running.
Dealer Programming
[94]Dealer Code
The default Dealer Code is
4567
. Program
a new 4-digit Dealer Code. When the panel
is defaulted the Dealer Code will be
changed back to the default Dealer Code of
4567
only if Dealer Code Lockout [96-1]
has not
been programmed.
[95]User 1 Code
The 1st User code is a program code as
well as an Arm/Disarm code. The default
User Code is
1234
. If User 1 Code
Lockout is programmed the User 1 Code
cannot be programmed from User Program
Mode.
[96]Dealer Options 1
(1) Dealer Code Lockout
- Program to
prevent the Dealer Code from changing
with a panel default.
(2) User 1 Code Lockout
- If programmed
the User 1 Code cannot be programmed
from User Program Mode.
(3) Household Fire
- Activates the
following UL required features:
There is a 4 hour re-sound of wireless
Smoke Low Battery and wireless Smoke
Supervisory system troubles.
An active System Battery test performed
every 4 hours instead of 24 hours and
Wireless Smoke Supervisory Timer is set
to 4 hours.
Fire Bell Timing is March Time.
Wireless Smoke Supervisory Time is
fixed at 4 hours.
(4) Fire Trouble on Fire LED
- Normally all
troubles are displayed on the
H
SYSTEM
TROUBLE LED, including Fire Trouble. If
required Fire Trouble can be displayed on the
Fire LED. Fire Trouble is indicated by a
steady
I
Fire LED.
[97]Dealer Options 2
(1) International Dialing Protocol
- No
dialing if no dial tone, 60 s between attempts
and 4 s wait for dial tone.
(2) Invert Bell Output
- Inverts the Bell
polarity and removes supervision from the
bell circuit.
(3) System Trouble Auto Restore
-
Normally, System troubles require
acknowledgment (View System Trouble) in
order to restore. If this option is selected
troubles will restore without requiring
acknowledgment.
(4) User 1 Code-Program only
- If enabled
User 1 Code will function only as the User
Program Code and will not Arm/Disarm the
panel.