Operation
Owner’s Manual for Generac PWRCell Inverter 15
Figure 3-8. Enabling and Disabling Devices (1 of 3)
3. Press the center button.
4. See Figure 3-9. Highlight Enable and press the
center button.
Figure 3-9. Enabling and Disabling Devices (2 of 3)
5. See Figure 3-10. Arrow right and press the center
button to select Confirm.
Figure 3-10. Enabling and Disabling Devices (3 of 3)
NOTE: Per UL1741, the PWRcell inverter may wait five
minutes or longer before beginning to export power after
the inverter has been enabled.
Mod. Settings Menu
Most REbus devices have user-adjustable parameters,
such as setpoints for charge, startup voltage, or PLM
channel. See Table 3-4 for available settings.
To access user-adjustable parameters:
1. Use the left and right arrows to navigate to the
desired device page.
2. See Figure 3-11. Highlight Mod. Settings and
press the center button to select
Figure 3-11. Internet Device Page
NOTE: After selecting Mod. Settings it may take a
moment for the settings to load.
3. See Figure 3-12. Use the up and down arrows to
scroll through available settings.
4. Highlight the desired setting and press the center
button to select.
5. Use the up and down arrow keys to adjust the
value of the setting.
NOTE: Press the center button to deselect a setting at
any time and resume scrolling.
Figure 3-12. Mod. Settings Menu (1 of 3)
6. To save the settings, highlight Commit and press
the center button.
Inverter
PWRcell 2P Inv.
2.4kWh
248V
0W
-02
Disabled
AC Power:
AC Voltage:
E-total:
009970
PWRcell 2P Inv. Menu
Mod. Settings
RCPn: 000100073212
< EXIT SCROLL > NEXT • SELECT
Enable
Calibrate CTs
009971
Enable
PWRcell 2P Inv. Menu
Mod. Settings
Calibrate CTs
RCPn: 00010003XXXX
< EXIT SCROLL > NEXT • SELECT
Enable
Cancel Confirm
009972
Disable
PWRcell 2P Inv. Menu
Mod. Settings
RCPn: 000100073212
< EXIT SCROLL > NEXT • SELECT
Calibrate CTs
010234
009975

Other manuals for Generac Power Systems PWRcell XVT076A03

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems PWRcell XVT076A03 and is the answer not in the manual?

Generac Power Systems PWRcell XVT076A03 Specifications

General IconGeneral
BrandGenerac Power Systems
ModelPWRcell XVT076A03
CategoryInverter
LanguageEnglish

Related product manuals