DRIVE
BELTS
The
engine
drives
the
generator
rotor
by
means
of
a
pulley
and
drive
belt
arrangement.
The
drive
train,
drive
belt
and
pulleys
are
warranted
for
the
life
of
the
gener¬
ator.
Drive
belt
tension
was
properly
adjusted
before
the
unit
was
shipped
from
the
factory.
If
you
suspect
that
drive
belt
tension
is
incorrect,
contact
an
authorized
service
facility.
EXERCISING
THE
GENERATOR
Generac
recommends
that
you
start
and
operate
the
generator
at
least
once
every
seven
days.
Let
the
unit
run
for
at
least
30
minutes
to
"exercise"
the
engine.
OUT
OF
SERVICE
PROTECTION
If
you
cannot
exercise
the
generator
every
seven
days
and
it
is
to
be
out
of
service
longer
than
30
days,
prepare
the.generator
for
storage
as
follows:
Start
the
engine
and
let
it
warm
up.
Close
the
fuel
shutoff
valve
in
the
fuel
supply
line
and
let
the
engine
"run
out
of
gas."
While
the
engine
is
still
warm
from
running,
drain
the
oil
completely.
Refill
crankcase
with
SAE
10W-
30
oil
having
API
classification
"For
Service
SF."
Attach
a
tag
to
the
engine
indicating
the
viscosity
and
classification
of
the
oil
in
the
crankcase.
Remove
spark
plugs
and
pour
about
two
or
three
tablespoons
of
clean,
fresh,
engine
oil
into
spark
plug
threaded
openings.
Crank
engine
several
times
to
distribute
oil,
then
install
and
tighten
spark
plugs.
Remove
the
battery
and
store
in
a
cool,
dry
room
on
a
wooden
board.
Never
store
the
battery
on
any
concrete
or
wooden
floor.
Clean
and
wipe
the
entire
generator.
RETURN
THE
UNIT
TO
SERVICE
AFTER
STORAGE
To
return
the
unit
to
service
after
storage,
proceed
as
follows:
Check
tag
on
engine
for
oil
viscosity
and
classifica¬
tion.
Verify
that
the
correct
recommended
oil
is
used
in
engine.
If
necessary,
drain
and
refill
with
proper
oil.
Check
battery.
Fill
all
cells
to
the
proper
level
with
distilled
water.
DO
NOT
USE
TAP
WATER
IN
THE
BATTERY.
Recharge
battery
to
100%
state
of
charge,
or,
if
defective,
replace
the
battery.
Turn
OFF
all
electrical
loads,
add
gasoline
if
neces¬
sary,
then
start
the
engine.
Let
engine
warm
up.
Apply
electrical
loads
to
at
least
50%
of
the
unit’s
rated
wattage
capacity.
When
engine
is
thoroughly
warmed
up,
shut
it
down.
THE
GENERATOR
IS
NOW
READY
FOR
SERVICE.
-
1
5
-

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems Q-70G Series and is the answer not in the manual?

Generac Power Systems Q-70G Series Specifications

General IconGeneral
BrandGenerac Power Systems
ModelQ-70G Series
CategoryInverter
LanguageEnglish

Related product manuals