EasyManuals Logo
Home>Generac Power Systems>Inverter>Q-70G Series

Generac Power Systems Q-70G Series User Manual

Generac Power Systems Q-70G Series
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
GENERAL
SAFETY
RULES
_
THE
MANUFACTURER
SUGGESTS
THAT
THESE
•'RULES
1
'
FOR
SAFE
OPERATION
BE
COPIED
AND
POSTED
IN
POTENTIAL
HAZARD
AREAS
OF
THE
INDUSTRIAL
VEHICLE.
SAFETY
SHOULD
BE
STRESSED
TO
ALL
OPERATORS
AND
POTENTIAL
OPERATORS
OF
THIS
EQUIPMENT.
Study
these
SAFETY
RULES
carefully
before
operating
or
servicing
applicable
equipment.
Become
familiar
with
this
Owner’s
Manual
and
with
your
generator.
Safe,
efficient
and
reliable
operation
can
only
be
achieved
if
generator
is
properly
installed,
operated
and
main¬
tained.
Many
accidents
are
caused
by
failing
to
follow
simple
and
fundamental
rules
or
precautions.
The
man¬
ufacturer
suggests
that
these
GENERAL
SAFETY
RULES
be
copied
and
posted
in
potential
hazard
areas
of
the
industrial
vehicle.
Safety
should
be
stressed
to
all
operators
and
potential
operators
of
equipment.
The
manufacturer
cannot
possibly
anticipate
every
pos¬
sible
circumstance
that
might
involve
a
hazard.
The
warnings
in
this
Manual
and
on
tags
and
decals
affixed
to
the
unit
are,
therefore,
not
all-inclusive.
If
you
use
a
procedure,
work
method
or
operating
technique
Generac
does
not
specifically
recommend,
you
must
satisfy
yourself
that
it
is
safe
for
you
and
others.
You
must
also
make
sure
the
procedure,
work
method
or
operating
technique
that
you
chose
does
not
render
the
generator
to
be
unsafe.
For
fire
safety,
the
industrial
mobile
generator
must
be
properly
installed
and
maintained.
Installation
must
always
remain
in
compliance
with
applicable
codes
and
standards.
In
addition,
the
generator
must
be
installed
in
conformance
to
the
manufacturer’s
detailed
installation
instructions.
Following
installation,
nothing
must
be
done
that
might
render
the
generator
in
noncompliance
with
such
codes,
standards
and
instructions.
The
RV
generator
produces
extremely
high
and
dangerous
electrical
voltages
and
can
cause
dan¬
gerous,
and
possibly
fatal,
electrical
shock.
Avoid
contact
with
bare
wires,
terminals,
etc.
while
the
unit
is
running.
If
you
must
work
around
an
operat¬
ing
generator,
stand
on
an
insulated,
dry
surface
to
reduce
shock
hazard.
Never
work
on
this
equipment
or
handle
any
elec¬
trical
device
while
standing
in
water,
while
barefoot,
or
while
hands
or
feet
are
wet.
Dangerous
electri¬
cal
shock
will
result.
Have
the
generator
properly
grounded
(bonded)
during
installation
onto
the
vehicle,
either
by
solid
mounting
to
the
vehicle
frame
or
chassis
or
by
means
of
an
approved
bonding
conductor.
DO
NOT
disconnect
the
bonding
conductor,
if
so
equipped.
DO
NOT
reconnect
the
bonding
conduc¬
tor
to
any
generator
part
that
might
be
removed
or
disassembled
during
routine
maintenance.
If
the
grounding
conductor
must
be
replaced,
use
only
a
flexible
conductor
that
is
of
No.
8
AWG
copper
wire
minimum.
Inspect
the
generator
periodically.
Repair
or
re¬
place
all
damaged
or
defective
parts
immediately.
In
case
of
accident
caused
by
electric
shock,
shut
down
the
source
of
electrical
power
down
at
once.
If
this
cannot
be
done,
free
victim
from
live
conduc¬
tor.
AVOID
DIRECT
CONTACT
WITH
THE
VIC¬
TIM.
Use
a
dry
board,
dry
rope,
or
other
non-con¬
ducting
implement
to
free
the
victim
from
live
con¬
ductor.
If
victim
is
unconscious,
apply
CPR
(cardio¬
pulmonary
resuscitation)
and
get
medical
help.
Inspect
fuel
system
frequently
for
leaks
or
damage.
Repair
or
replace
any
damaged
or
leaking
compo¬
nent
immediately.
Never
attempt
to
change,
alter
or
modify
the
generator
fuel
system
in
any
way
that
might
affect
safety
or
compliance
with
applicable
codes
and
standards’.
The
generator
engine
gives
off
DEADLY
carbon
monoxide
gas
through
its
exhaust
system.
This
dangerous
gas,
if
breathed
in
sufficient
concentra¬
tions,
can
cause
unconsciousness
or
even
death.
This
exhaust
system
must
have
been
properly
in¬
stalled,
in
strict
compliance
with
applicable
codes
and
standards.
Following
installation,
you
must
do
nothing
that
might
render
the
system
unsafe
or
in
non-compliance
with
such
codes
and
standards.
The
generator
compartment
must
be
completely
vapor
sealed
from
vehicle
interior.
There
must
be
no
possibility
of
exhaust
fumes
entering
the
vehicle
interior.
Never
operate
this
equipment
with
a
leak¬
ing
or
defective
exhaust
system.
Never
use
the
generator
or
any
of
its
parts
as
a
step.
Stepping
on
the
unit
can
stress
and
break
parts
and
may
result
in
dangerous
operating
conditions
from
leaking
exhaust
gases,
fuel
leakage,
oil
leakage,
coolant
leakage,
etc.
Do
not
smoke
around
the
generator.
Wipe
up
any
fuel,
oil
and
coolant
spills
immediately.
Never
leave
oily
or
fuel
soaked
rags
in
the
generator
compart¬
ment
or
on
the
generator
itself.
Keep
the
area
around
the
generator
clean
and
free
of
debris.
Adequate
ventilation
is
required
to
expel
toxic
fumes
and
gasoline
vapors
from
the
generator
com¬
partment.
Do
not
alter
the
installation
of
this
equip¬
ment
in
any
manner
that
might
obstruct
air
and
ventilation
openings.
Such
openings
must
be
kept
clear
and
unobstructed.
Keep
hands,
feet,
clothing,
etc.,
away
from
drive
belts,
fans
and
other
moving
parts
of
this
equip¬
ment.
Never
remove
any
drive
belt
or
fan
guards
while
the
unit
is
operating.
Some
generators
may
use
LP
gas
(propane)
as
a
fuel.
LP
gas
is
highly
EXPLOSIVE.
The
gas
is
heavier
than
air
and
tends
to
settle
in
low
areas
where
even
the
slightest
spark
can
ignite
the
gas
and
cause
an
explosion.
Before
performing
any
maintenance
on
the
gener¬
ator
set,
disconnect
its
battery
cables
to
prevent
accidental
start
up.
Disconnect
the
cable
from
the
battery
post
indicated
by
a
NEGATIVE,
NEG
or
(-)
first.
Reconnect
that
cable
last.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems Q-70G Series and is the answer not in the manual?

Generac Power Systems Q-70G Series Specifications

General IconGeneral
BrandGenerac Power Systems
ModelQ-70G Series
CategoryInverter
LanguageEnglish

Related product manuals