TROUBLESHOOTING
PROBLEM
POSSIBLE
CAUSE(S)
REMEDY
Engine
won’t
crank
1.
15
amp
fuse
blown.
2.
Loose,
corroded
or
defective
battery
cable{s).
3.
Battery
is
discharged
or
defective.
4.
Defective
starter
contactor.
5.
Defective
starter
motor.
6.
Defective
control
relay
(CR1
)
.
1
.
Replace
blown
fuse.
2.
Tighten,
clean
or
replace,
as
necessaiy.
3.
Recharge
or
replace
battery.
4.
Replace
starter
contactor.
5.
Replace
starter
motor.
6.
Replace
control
relay.
Engine
cranks,
won't
start
1.
Out
of
fuel.
2.
Fuel
shutoff
valve
is
closed.
3.
Fuel
pump
not
operating.
4.
Automatic
choke
not
operating
properly.
5.
Engine
is
flooded.
6.
Fuel
filter
is
clogged.
7.
Defective
control
relay
(CR2).
8.
Engine
spark
plugs
defective.
9.
Bad
ignition
magneto
on
engine.
10.
Bad
carburetor.
11.
Dirty
air
cleaner.
1.
Refill
fuel
tank.
2.
Open
fuel
shutoff
valve(s).
3.
Repair
or
replace
pump.
4.
Repair,
replace
or
adjust.
5.
Wait
5*10
minutes;
try
again.
6.
Replace
filter
if
clogged.
7.
Replace
bad
relay
(CR2).
8.
Clean,
regap
or
replace
as
needed.
9.
Replace
if
defective.
10.
Adjust,
repair
or
replace.
11
.
Clean
or
replace
as
needed.
Engine
starts
hard,
runs
rough.
1.
Dirty
engine
air
cleaner.
2.
Automatic
choke
is
sticking.
3.
Defective
spark
plugs.
4.
Defective
ignition
magneto,
1
.
Clean
or
replace
as
needed.
2.
Free
choke
linkage
as
needed.
3.
Clean,
regap
or
replace.
4.
Replace
it
if
defective.
Engine
starts,
then
shuts
down.
1
.
Engine
oil
level
is
low
2.
Bad
control
relay
(CR1).
3.
Bad
low
oil
pressure
switch.
4.
Bad
control
relay
(CR2).
5.
Water
in
fuel.
1
Add
oil
as
needed.
2.
Replace
if
bad
(CR1).
3.
Replace,
if
bad.
4.
Replace
bad
relay
(CR2).
5.
Drain
fuel
tank
and
refill.
No
AC
output
voltage
1.
Main
breaker(s)
open.
2.
Transfer
switch
(if
so
equipped)
is
set
to
wrong
position.
3.
Failure
in
vehicle
electrical
system.
4.
Generator
component
failure.
1.
Close
main
breaker(s).
2.
Reset
transfer
switch.
3.
See
vehicle
manual.
4
.
Contact
authorized
service
facility.
-
1
6
-

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems Q-70G Series and is the answer not in the manual?

Generac Power Systems Q-70G Series Specifications

General IconGeneral
BrandGenerac Power Systems
ModelQ-70G Series
CategoryInverter
LanguageEnglish

Related product manuals