EasyManua.ls Logo

Genius Blizzard 900 C - Installation of the Limit Switches; Programming

Genius Blizzard 900 C
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BLIZZARD 500-900 C 18 532103 - Rev.B
30
13 14 1615 17
M
COM
OPEN
CLOSE
N
LAMP
60W max
31
2.5
J6
OPEN A
OPEN B
FSW OP
FSW CL
STOP
EDGE
TX-FSW
W.L.
24 V
500 mA
max
123456789101112
{
2.5
29
J1
Translation of the original instructions
ENGLISH
Translation of the original instructions
ENGLISH
6.1 TERMINAL BOARDS AND CONNECTORS
Do not exceed the maximum load of the outputs.
J1
Terminal board for connecting the inputs and outputs (29).
10 J1 - Inputs and outputs
INPUTS
1 OPEN A N.O. contact; if active, it commands the total opening of the gate.
If multiple contacts are used, they must be connected in parallel
(30).
2 OPEN B N.O. contact; if active, it commands the partial opening of the gate.
If multiple contacts are used, they must be connected in parallel
(30).
3 FSW OP N.C. contact for photocells during opening (§ 6.2).
4 FSW CL N.C. contact for photocells during closing (§ 6.2).
5STOPN.C. stop contact (§ 6.2).
6 EDGE N.C. contact for sensitive edges (§ 6.2).
OUTPUTS:
7-8 - Negative for accessories.
9-10 + Positive for accessories (24 V
"
/500 mA max).
11 TX-FSW Fail-safe Test Output. Provides a negative pole for accessories supply
(100 mA max). It can be used to carry out a functional test of the
safety devices connected to the inputs FSW OP, FSW CL and EDGE. If
the test fails, the gear motor does control the movement.
Please refer to § 6.2 e § 7.4-15.
12 W.L. Programmable output (100 mA max). When active, it provides a
negative for accessories. Default: indicator lamp (§ 7.4-15-SP).
J2
Rapid connector for inserting the GENIUS 5-pin radio receiver (option-
al accessory). Plug in the receiver only when the board is not powered.
J3
Rapid connector for inserting the encoder (optional accessory in
some models).
J4
Rapid connector for inserting the start-up capacitor. Alternatively, the
capacitor can be connected across terminals 14 and 15 of J6.
J5
Rapid connector for inserting the magnetic limit stop sensor.
J6
Terminal board for connecting the motor and flashing light (31).
The cable of the electric motor is connected during production.
11 J6 - Motor and Flashing Light
MOTOR OUTPUT:
13 COM Common Grey
14 OPEN Opening Black
15 CLOSE Closing Brown
FLASHING LIGHT OUTPUT:
16 N Neutral
17 LAMP Flashing lamp phase (230/115 V~): output active
during movement and during the pre-flashing set
in Programming (§ 7.4-15-PF).
Example of N.O. contacts connected in parallel
Example of N.C. contacts connected in series
https://smartel.ua