EasyManua.ls Logo

Genius Blizzard 900 C - 9 Operating Logics

Genius Blizzard 900 C
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BLIZZARD 500-900 C 27 532103 - Rev.B
Translation of the original instructions
ENGLISH
Translation of the original instructions
ENGLISH
LOGIC A: AUTOMATIC
GATE STATUS
PULSES SAFETY DEVICES
OPEN A OPEN B STOP FSW OP FSW CL FSW CL/OP EDGE
CLOSED
Opens. Closes after
the pause time
Opens partially.
Closes after the
pause time
No effect (OPEN
disabled)
No effect (OPEN
disabled)
No effect No effect (OPEN
disabled)
No effect (OPEN
disabled)
WHEN OPENING
No effect No effect Stops
§ 7.4-15-oP
No effect Stops. Opens when
disengaged
Reverses to closing
for 2 seconds
OPEN IN PAUSE
Resets pause time Resets pause time Stops No effect Resets pause time
(OPEN disabled)
Resets pause time
(OPEN disabled)
No effect (OPEN
disabled)
WHEN CLOSING
Opens Opens Stops No effect (memo-
rizes OPEN)
§ 7.4-15-Ph
Stops. Opens when
disengaged
Reverses to opening
for 2 seconds*
STOPPED
Closes Closes No effect (OPEN
disabled)
No effect No effect No effect (OPEN
disabled)
No effect (OPEN
disabled)
LOGIC AP: AUTOMATIC STEPBYSTEP
GATE STATUS PULSES SAFETY DEVICES
OPEN A OPEN B STOP FSW OP FSW CL FSW CL/OP EDGE
CLOSED
Opens. Closes after
pause time
Opens partially;
closes after pause
time
No effect (OPEN
disabled)
No effect (OPEN
disabled)
No effect No effect (OPEN
disabled)
No effect (OPEN
disabled)
WHEN OPENING
Stops Stops Stops
§ 7.4-15-oP
No effect Stops. Opens when
disengaged
Reverses to closing
for 2 seconds
OPEN IN PAUSE
Stops Stops Stops No effect Resets pause time
(OPEN disabled)
Resets pause time
(OPEN disabled)
No effect (OPEN
disabled)
WHEN CLOSING
Opens Opens Stops No effect (memo-
rizes OPEN)
§ 7.4-15-Ph
Stops. Opens when
disengaged
Reverses to opening
for 2 seconds*
STOPPED
Closes Closes No effect (OPEN disa-
bled)
No effect No effect No effect (OPEN disa-
bled)
No effect (OPEN disa-
bled)
LOGIC S: AUTOMATIC SAFETY
GATE STATUS PULSES SAFETY DEVICES
OPEN A OPEN B STOP FSW OP FSW CL FSW CL/OP EDGE
CLOSED
Opens. Closes after
pause time
Opens partially. Clos-
es after pause time
No effect (OPEN disa-
bled)
No effect (OPEN disa-
bled)
No effect No effect (OPEN disa-
bled)
No effect (OPEN disa-
bled)
WHEN OPENING
Closes Closes Stops
§ 7.4-15-oP
No effect Stops. Opens when
disengaged
Reverses to closing
for 2 seconds
OPEN IN PAUSE
Closes Closes Stops No effect Closes after 5 sec.
(OPEN disabled)
Closes after 5 sec.
(OPEN disabled)
No effect (OPEN disa-
bled)
WHEN CLOSING
Opens Opens Stops No effect (memorizes
OPEN)
§ 7.4-15-Ph
Stops. Opens when
disengaged
Reverses to opening
for 2 seconds*
STOPPED
Closes Closes No effect (OPEN disa-
bled)
No effect No effect No effect (OPEN disa-
bled)
No effect (OPEN disa-
bled)
9. OPERATING LOGICS
In logics A, AP and S, the maintained commands OPEN A and OPEN
B prolong the OPEN IN PAUSE status until they are disabled (E.g. by
TIMER). The effects on the other active inputs are shown in brackets.
https://smartel.ua