Geometrics Inc. G-882 Cesium Marine Magnetometer Page
Command Format: Description:
----------------- ----------- ----------------------------------
Set Hour: Byte 1: 'H' Set the hour
2: x MS digit of number ('0'-'2')
3: x LS digit of number ('0'-'9')
4: CR carriage return
Set Minute: Byte 1: 'M' Set the minute
2: x MS digit of number ('0'-'5')
3: x LS digit of number ('0'-'9')
4: CR carriage return
Set Second: Byte 1: 'S' Set the second
2: x MS digit of number ('0'-'5')
3: x LS digit of number ('0'-'9')
4: CR carriage return
Find counters: Byte 1: 'F' Find and assign counter numbers
2: '0' assign first counter as # 0 (MSB)
3: '0' LSB
4: CR carriage return
Set Preamble Byte 1: 'P' Set the preamble char ('$')
2: x The desired character
3: CR carriage return
Jump to debug Byte 1: 'X' first char of 'XBUG' string
2: 'B' 2'cnd char
3: 'U' 3'rd char
4: 'G' 4'rth char
5: CR carriage return