56
Local Lock Mode: Remains locked. The locked state cannot be cleared through GV-
ASManager.
Fixed Card Mode: Grants access after the card is presented or the passcode is
entered, and ignores the authentication schedule of GV-ASManager.
Fixed Card + PIN Mode: Grants access after the user presents the card and enters
the card’s PIN code, and ignores the authentication schedule of GV-ASManager.
Fixed Card/Common mode: Grants access after the user presents the card or
enters the door’s password, and ignores the authentication schedule of GV-
ASManager.
Authentication Schedule Mode: Follows the authentication schedule set on GV-
ASManager.
Local Lock Down: Locks down the door. This mode overrides the Authentication
Schedule and the door can only be opened by presenting the assigned access card.
[Series Function (APB & Fire)] This option lets you set the Anti-Passback function and fire
sensor function across multiple door controllers. The Anti-Passback means that a card used
on an entry door cannot access the same entry door again unless it has been used on a
corresponding exit door.
Enable/Disable: Enables or disables the Anti-Passback function and fire sensor
function.
Info IP: Enter the IP address of the next corresponding controller.
Note: GV-CS1320 does not support fire sensor inputs. However, the output of GV-CS1320
will be triggered when the fire sensors on one door of its associated controller is triggered.