Installationmodeoftheboiler
Testingmode
Installationmodeservesforsettingupvariousparametersofboileroperation.Thismode
isactivatedbypressingthe______buttononthecontrolboardformorethan3seconds.
ActivatedinstallationmodeissignalledbyflashingsignalizationLEDdiodeabovethe
button.Parametersareselectedbypressingthebutton_______.Changeofaparameteris
donebypressingbuttons+/-nearthesymbol______.Recordtomemoryoftheboileris
confirmedbypressingthebutton______in5secondsfromchoosingtherightvalue.This
timeperiodisindicatedbyflickeringredLEDdiodeabovethisbutton.
Ifthechangeisnotconfirmed,thevalueisnotrecordedintothememoryandlastvalue
donebeforethischangeisvalid.
Theinstallationmodeisfinishedbypressingthebutton_______incasetheredLED
diodeabovethisbuttonisnotflickering.Theinstallationmodeisalsofinishedifthereis
noactivityformorethan1minute.
Listofparameters:
1Raiseoftemperatureatstart(°C/min)inheatingmode(0-60)4
2Anticyclingtimeinheatingmode(s)(0-255)90
3Kpfactorinheatingmode(-)(0-255)2
4Kifactorinheatingmode(-)(0-255)62
5Kpfactorinhotwatermode(-)(0-255)3
6Kifactorinhotwatermode(-)(0-255)93
7Startingoutput(%)(0-70)50
8Kpfactoroftheventilator(-)(0-255)35
9Kpfactoroftheventilator(-)(0-255)230
10Heating-set-upparameterbyoutsidetemperature(°C)(20-40)30
11Currentheatingtemperature(°C)
12Run-outofthepumpinheatingmode(min)(1-20)5
13Currenthot-watertemperature(°C)
14Maximumoutputoftheboilerinheatingmode(%)(0-100)100
15Heatingcurvebyoutsidetemperature(-)(0-10)0
16Run-outofthepumpinhot-watermode(s)(0-255)30
17Hysteresisinheatingmode(°C)(0-10)3
18Hysteresisinhot-watermode(°C)(0-20)5
19Maximumvalueoftemperatureinheatingmode(°C)(20-90)80
Testingmodeisactivatedbypressingthebutton_______formorethan3seconds.The
functionoftestingmodeissignalledbyflickeringsignalizationLEDdiodeatthisbutton.
Duringtestingmodeitispossible,withbuttons+/-,tosetupoutputatthesymbol
_______whichisgiveninpercentanddisplayed.Ifyouwanttofinishthetestingmode,
youcandothatwiththebutton_______.Durationofthetestingmodecanbesetuporit
finishesautomaticlyiffor30minutesthereisnochange.
Par.No.DescriptionSet-uprangeSelectedvalue