3.3 Charging procedure
Only charge GESIPA
®
batteries at a temperature between 0 °C and 40 °C!
Take the quick charger out of its packaging and connect to the power supply. Pay atten-
tion to the voltage specied on the rating plate!
Using minimum force, insert the GESIPA
®
battery in the correct position (+pole to +pole)
into the charger.
The charging operation starts automatically.
Steady green Battery charged / trickle charging
Flashing green Charging
Steady red Impermissible charging temperature
Flashing red Battery defective
Battery type Part No. Charging time*
1.3 Ah 143 4921 approx. 50 min
2.6 Ah 145 7269 approx. 100 min
* Charging times may vary depending on the residual capacity and the battery temperature.
3.4 Battery care
To achieve an optimum charge, allow the battery to cool down before inserting it in the
charger.
The GESIPA
®
battery can be recharged approx. 1000 times and reaches its full capacity
after several charges.
Do not insert the battery into the charger after each use.
Only charge the battery when it is discharged and blind rivet nuts can no longer be set.
Only recharge the battery after a prolonged idle period.
Signicantly shorter battery operating times, despite proper recharging, indicate that the
battery needs to be replaced.
Store batteries in a dry place where there is no danger of frost. The optimum operating
temperature range is 10 °C to max. 50 °C.