26
GB
4.2 No spent mandrel disposal
Cause Corrective measures
Wrong nosepiece (No. 1) used Exchange according to table (see 1.4)
Nosepiece worn (No. 1) Replace
Mandrel jammed in jaws (No. 4) Release mandrel, clean jaws and jaw
housing, oil sliding surface or replace jaws
(see 1.8)
Inside of steel head sleeve (No. 2) dirty Clean (see 1.8)
Spent mandrel container (No. 32) full Detach and empty
Passageway blocked Remove jammed mandrels and check for
trouble-free ejection (see 1.8)
4.3 Red lamp indicates fault
When pressing the trigger button
Cause Corrective measures
Riveting tool not in front end position Release trigger button
During pulling operation
Cause Corrective measures
Overload Use tool within working range as specied in
table (see 1.4.)
Electronics overheated Allow riveting tool to cool down in air
Battery discharged Charge or replace
After releasing the trigger button
Cause Corrective measures
Front end position not reached Tighten jaw mechanism (see 1.8 and 4.2)
Caution!
If faults occur that are indicated by the red lamp and cannot be rectied as described above,
have the riveting tool repaired by a skilled technician or send it in to the manufacturer.