TROUBLESHOOTING
It could be possible, your sealer does not function as it should.
Attention! The impulse-sealer should be disconnected from the mains before opening
the housing. Servicing and repairs should only be done by the dealer or by sufficient
technical schooled employees. In any case, the sealer should be disconnected from the
mains.
1. The heating-bar does not heat up.
Check if the sealer is connected to the mains.
Check the connection between the heating-bar and the transformer.
Check the fuse on the control-plate.
2. The seal melts and the material sticks to the pressure-bar.
Reduce the sealing-time.
3. The seal is not strong enough.
Increase the sealing-time and keep the foil without wrinkles.
Increase the pressure from the pressure-bar by screwing the two distance-screws
more into the supporting-studs.
TECHNICAL SPECIFICATIONS:
Dimensions ( L x W x H ) 410 x 300 x 195 mm
Sealing-time range 0-5 seconds
Sealing width 10 mm
Power consumption 870 W
Power supply 220-230V / 50 Hz
Fuse 5 A
Weight 8,5 kg
Every of our impulse- sealer is being built and tested according to the guidelines of the
German TÜV.
GS100200-GB-007.doc 04-99