6 Montageanleitung GC 302 R 123457, 70705-9-9521 Ä-St.1
5
S
ensor Configuration
Without addressing:
Parameter
Step 1
Step 2
Field size
Functionality
Field geometry
Press [<] briefly
Press [>] briefly
Press [<] and [>] briefly at the same time
Frequency of the flashing
green LED (1-9 times) indicates
the current parameter level
5.1 Configuration with keys
The status query is to find out what parameters have been set.
5.1.1 Status query with keys
5.2.2 Mode of operation
5.2 Configuration with remote control
Activation: Automatically after the sensor is connected to the supply
voltage or
Briefly disconnect the sensor from the supply voltage or
Press either key [<] or [>] on the sensor
Exiting: Press key combination or
Automatically after 30 min.
Note:
If no entry is made for 30 s, the connection is ended. The settings
made up to that point are saved.
1, 2, 3
small
4, 5, 6* medium
7, 8, 9 large
1* forwards, mounting height standard
2 forwards, mounting height high
3 backwards, mounting height standard
4 backwards, mounting height high
5 direction recognition OFF, mounting height standard
6 direction recognition OFF, mounting height high
7 forwards + MTO, mounting height standard (MTO, see chap. 7)
8 forwards + MTO, mounting height high (MTO, see chap. 7)
1 narrow field
2* wide field
Changing the functionality from level 6 to level 2:
1) Keep [<] and [>] pressed for 4 s, the green LED blinks once after 2 s,
once again after 4 s
2) Green LED flashes 6 times and thereby indicates the current parameter level
3) Press the key [<] four times in a row to decrease the parameter level
(green LED flashes twice and indicates the new parameter level)
4) Press [<] and [>] at the same time
The data transmission to and from the sensor is ensured by an IR interface. The
connection
between the remote control and the sensor can only be established
when the sensor is in configuration mode.
The sensor can be configured in two ways:
With keys on the sensor (basic settings)
With the remote control (complete setting options)
With addressing:
1. Press the start key
1. Cover the IR interface of the
remote control with your hand
2. Press the start key flashes
3. Release the IR interface
(remove hand)
4. Press the corresponding numerical
key ( to )
G and one of the keys 1 to 4 light up: Connection successfully established
G flashes: Connection not established
Activate configuration mode
Hold remote control closer to the sensor and point directly at it
Check batteries in remote control
No keys light up
Check/replace batteries in remote control
5.2.3 Setting / changing parameters
Keep the door open manually for 15 min. when making settings.
Afterwards, the door will close if no object is in the detection area
Door closes when no object is in the detection area, afterwards
standard operation
Configuration mode is ended, door closes when no object is in the
detection area, afterwards standard operation
After the connection has been successfully established, the parameters of the
sensor can be changed.
* Factory setting
General procedure
Changing the field size: Press [<] and [>] for 2 s
Changing the functionality: Press [<] and [>] for 4 s
Changing the field geometry:Press [<] and [>] for 6 s
Example
Restore factory settings: Press [<] and [>] for 8 s
Configuration mode
+
A 3
Establishing the connection
Each sensor can be assigned an address (1*, 2, 3 or 4). Different addresses are
necessary when several sensors are within the range of a remote control.
Address 1*
Address 2
Address 3
Address 4
5.2.1 Sensor addressing
G
G G
1 4
+
A 1
+
A 2
+
A 3
Numerical keys to
1 9
IR interface (infrared)
Control keys to
A F
Start
G
LevelLevel
Level
[>]
[<]
1) Keep [<] and [>] pressed for a corresponding length of time; every 2 s the
green LED will flash once
2) Frequency of the flashing green LED (1-9 times) indicates current parameter
level
3) The parameter level can be decreased or increased with [<] and [>]
respectively
4) Press [<] and [>] briefly to exit the programming mode (settings are saved)
Note:
If no key is actuated for 25 s, the programming mode is automatically exited
however the sensor is still in the configuration mode. The settings made up to
that point are saved.