Loading...
4
7
8
Range
à Adjust according to requirement.
à Depends on the direction of movement, size and material/type
of object to be detected.
5
6
60 cm
60 cm
Output
Acoustic
signal
DIP
12
DIP
3
DIP
123
Colour of LED
Colour of LED
No detection Detection
DIP
123
O Blue
Blue O
DIP
123
Blue Green
DIP
123
O Green
DIP
123
Green O
DIP
123
O O
DIP
123
Green Red
DIP
123
Re
dG
reen
DIP
123
1
2
On
Input
O On O
Pulse mode (NO)
Recommended for
automatic door drives
Pulse mode (NC)
Toggle mode (NC)
Control INPUT
Is activated via an external contact. When the contact is
closed, the switching behaviour changes (refer also to sec-
tion “Door control”) and the LED display lights up red.
Output modus
LED according to DIP switch settings
The input signal must be a potential-free contact
(no voltage).
Acoustic feedback
Toggle mode (NO)
Recommended for
switching applications