DescriptionGC 363 R / SF
1.3 Safety conscious working
à Secure workplace against unauthorised entry.
à Watch swivelling range of long system parts.
à Secure the cover/drive panels against falling.
à Attach safety stickers to glass door leaves.
à Danger of injury with opened drive. Hair, clothing, cables, etc. can be
drawn in by rotating parts.
à Danger of injury caused by unsecured crushing, impact, drawing-in or
shearing spots.
à Danger of injury due to broken glass.
à Danger of injury due to sharp edges in the drive.
à Danger of injury during installation through freely moving parts.
1.4 Environmentally conscious working
à When disposing of the door system, separate the dierent materials and
have them recycled.
2 Description
The combined detectors GC 363 R / SF have a radar eld for detecting
movement and an infrared eld for protection.
It is not possible for several systems to inuence each other and result in a
hazard. Unintentional stop signals are possible where detectors are mount-
ed next to one another as their infrared measuring ranges overlap and each
sensor could activate the other. This inuence is kept to a minimum by
dierent frequency settings.
The optional interface GC 363 S is exclusively for use with the GC 363 SF
combined detector. The interface permits several combined detectors to be
switched in series for FR sliding doors with large opening widths.
Variant GC363 R GC363 SF
Black 151237 151239
According to RAL 151238 151240