& Fan Control Use Temperature Input
Allows you to select the reference temperature for fan speed control.
& Temperature Interval
Allows you to select the temperature interval for fan speed change.
& Fan Control Mode
Auto Lets the BIOS automatically detect the type of fan/pump installed and sets the optimal
controlmode.(Default)
Voltage Voltage mode is recommended for a 3-pin fan.
PWM PWMmodeisrecommendedfora4-pinfan.
& Fan Stop
Enables or disables the fan/pump stop function. You can set the temperature limit using the temperature
curve.Thefanorpumpstopsoperationwhenthetemperatureislowerthanthelimit.(Default:Disabled)
& Temperature
Displaysthecurrenttemperatureoftheselectedtargetarea.
& Fan Speed
Displayscurrentfanspeeds.
& Flow Rate
Displaystheowrateofyourwatercoolingsystem.
& Temperature Warning Control
Setsthewarningthresholdfortemperature.Whentemperatureexceeds the threshold, BIOS will emit
warningsound.Optionsare:Disabled(default),60
o
C/140
o
F, 70
o
C/158
o
F, 80
o
C/176
o
F, 90
o
C/194
o
F.
& Fan Fail Warning
Allows the system to emit warning sound if the fan is not connected or fails. Check the fan condition or fan
connectionwhenthisoccurs.(Default:Disabled)
- 27 -