Chapter 3 Appendix
Beforeyoubegin,pleasepreparethefollowingitems:
• AtleasttwoSATAharddrivesorSSDs.
(Note)
(To ensure optimal performance, it is recommended that you
use two hard drives with identical model and capacity).
• Windowssetupdisk.
• Motherboard driver disk.
• A USB thumb drive.
ConguringtheOnboardSATAController
A.InstallingSATAharddrive(s)inyourcomputer
Installtheharddrives/SSDsintheIntel
®
Chipset controlled connectors on the motherboard. Then connect the
power connectors from your power supply to the hard drives.
B.ConguringSATAcontrollermodeinBIOSSetup
MakesuretoconguretheSATAcontrollermodecorrectlyinsystemBIOSSetup.
Steps:
1. Go to Peripherals\SATAAndRSTConguration, make sure SATA Controller(s) is enabled. To create
RAID,setSATA Mode Selection to Intel RST Premium With Intel Optane System Acceleration. Then
save the settings and restart your computer.
2. TocongureUEFIRAID,followthestepsin"C-1."ToenterthelegacyRAIDROM,referto"C-2"formore
information. Finally, save the settings and exit BIOS Setup.
The BIOS Setup menus described in this section may differ from the exact settings for your motherboard.
The actual BIOS Setup menu options you will see shall depend on the motherboard you have and
the BIOS version.
3-1 ConguringaRAIDSet
RAID Levels
(Note) AnM.2PCIeSSDcannotbeusedtosetupaRAIDseteitherwithanM.2SATASSDoraSATAharddrive.
RAID 0 RAID 1
Minimum
Number of Hard
Drives
≥2 2
Array Capacity
Number of hard drives
* Size of the smallest
drive
Size of the smallest
drive
Fault Tolerance No Yes
C-1.UEFIRAIDConguration
Steps:
1. In BIOS Setup, go to BIOS and set Windows 8/10 Features to Windows 8/10 and CSM Support to Disabled.
Save the changes and exit BIOS Setup.
2. After the system reboot, enter BIOS Setup again. Then enter the Peripherals\Intel(R) Rapid Storage
Technology sub-menu.
3. On the Intel(R)RapidStorageTechnologymenu,press<Enter>onCreate RAID Volume to enter the Create RAID
Volume screen. Enter a volume name with 1~16 letters (letters cannot be special characters) under the Name item and
press<Enter>.Then,selectaRAIDlevel.RAIDlevelssupportedincludeRAID0andRAID1(theselectionsavailable
depend on the number of the hard drives being installed). Next, use the down arrow key to move to Select Disks.
4. Under Select Disksitem,selecttheharddrivestobeincludedintheRAIDarray.Pressthe<Space>key
ontheharddrivestobeselected(selectedharddrivesaremarkedwith"X").Thensetthestripeblocksize.
The stripe block size can be set from 4 KB to 128 KB. Once you have selected the stripe block size, set the
volume capacity.
- 41 -