10. Specifications
Dimensions (W*H*D)
Weight
647*629*252mm
37kg
3/N/PE, 220/380, 230/400
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated grid output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
Max.efficiency
EU efficiency
Model
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Cooling concept
Max.operation altitude
AC connection
Grid connection standard
DC connection
1100
3*32
3*40
3/6
0.8leading~0.8lagging
50/60
98.5%
98.1%
Transformerless
1W
-25~+60
0~100%
IP66
Intelligent redundant fan-cooling
4000m
Display
Communication connections
Warranty
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
MC4 connector
OT Terminal
LCD, 2×20 Z
RS485, Optional: Wifi, GPRS,USB*
5 years (extand to 20 years)
600
25000
27500
27500
38.0/36.1
41.8
THDi (at rated output power)
<3%
Start-up voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
200~1000
180
G98 or G99, VDE-AR-N 4105 / VDE V 0124,
EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1, TOR,
EIFS 2018.2, IEC 62116, IEC 61727, IEC60068,
IEC 61683, EN 50530
S5-GC25K
Safty/EMC standard
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
10. Specifications
Dimensions (W*H*D)
Weight
647*629*252mm
3/N/PE, 220/380, 230/400
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated grid output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
Max.efficiency
EU efficiency
Model
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Cooling concept
Max.operation altitude
1100
3/6
0.8leading~0.8lagging
50/60
Transformerless
1W
0~100%
4000m
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
600
30000
33000
33000
45.6/43.3
50.2
THDi (at rated output power)
<3%
Start-up voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
180
S5-GC30K
Optional USB* :only for the brazilian market
200~1000
3*32
3*40
98.5%
98.1%
37kg
-25~+60
Intelligent redundant fan-cooling
AC connection
Grid connection standard
DC connection
Display
Communication connections
Warranty
MC4 connector
OT Terminal
LCD, 2×20 Z
RS485, Optional: Wifi, GPRS,USB*
5 years (extand to 20 years)
G98 or G99, VDE-AR-N 4105 / VDE V 0124,
EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1, TOR,
EIFS 2018.2, IEC 62116, IEC 61727, IEC60068,
IEC 61683, EN 50530
Safty/EMC standard
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
Optional USB* :only for the brazilian market