Questions and Answers

  • S
    Susan ScottSep 4, 2025
    What does OV-DC01 (1020 DATA:0001) mean on Ginlong Inverter?
    • M
      Mary PetersSep 4, 2025
      If your Ginlong Inverter displays OV-DC01 (1020 DATA:0001), check if the PV voltage is abnormal. Restart the system and check if the fault continues.
  • P
    Patrick Webster MDSep 18, 2025
    What does OV-G-V03 mean on my Ginlong solis S6 Inverter?
    • K
      kperezSep 18, 2025
      If your Ginlong Inverter displays OV-G-V03, restart the system and confirm if the fault continues.
  • M
    Mary RoseSep 16, 2025
    What does OV-G-V01 mean on my Ginlong solis S6?
    • A
      amandakentSep 16, 2025
      If your Ginlong Inverter displays OV-G-V01, confirm whether the power grid is abnormal and that the AC cable is properly connected. Restart the system and check if the fault persists.
  • G
    Greg LindseySep 14, 2025
    What does IGFOL-F mean on my Ginlong Inverter?
    • J
      Joseph RandallSep 14, 2025
      If your Ginlong Inverter displays IGFOL-F, confirm whether the power grid is abnormal. Also, check that the AC cable is properly connected. Restart the system and see if the fault persists.
  • B
    Brittany ForbesSep 12, 2025
    What does UN-Vbatt mean on my Ginlong solis S6?
    • M
      melanie52Sep 12, 2025
      If your Ginlong Inverter displays UN-Vbatt, restart the system and check if the fault persists. If the issue continues, contact the manufacturer's customer service.
  • B
    Becky MartinezSep 12, 2025
    What does INI-FAULT (1031 DATA:0000) mean on Ginlong solis S6 Inverter?
    • L
      loweryshawnSep 12, 2025
      If your Ginlong Inverter displays INI-FAULT (1031 DATA:0000), restart the system and check if the fault continues.
  • A
    amandaoliverSep 9, 2025
    What does OV-Vbatt mean on my Ginlong solis S6 Inverter?
    • K
      Kimberly WilsonSep 9, 2025
      If your Ginlong Inverter displays OV-Vbatt, verify the battery voltage is within standards. Measure the battery voltage at the inverter connection point. For further assistance, contact your battery manufacturer.
  • M
    Meagan ClarkSep 7, 2025
    What does NO-Battery mean on my Ginlong solis S6?
    • R
      Ryan WalkerSep 7, 2025
      If your Ginlong Inverter displays NO-Battery, check the information page to verify the battery voltage is within standards. Also, measure the battery voltage at the plug.
  • B
    Brenda DavisSep 5, 2025
    Why does my Ginlong solis S6 Inverter show a Fan Alarm?
    • S
      Susan MartinezSep 5, 2025
      If your Ginlong Inverter displays a Fan Alarm, check if the internal fan is working correctly or is jammed.
  • G
    gschwartzAug 20, 2025
    What to do if my Ginlong solis S6 shows a Surge Alarm?
    • Q
      qburtonAug 21, 2025
      If your Ginlong Inverter displays a Surge Alarm, it indicates a grid side fault. Restart the device. If the problem persists, contact the manufacturer's customer service.

Ginlong solis S6 Series Specifications

General IconGeneral
Rated Grid Frequency50Hz/60Hz
THDi<3%
DC SwitchYes
TopologyTransformerless
Number of MPPT2
Rated Grid Voltage230V
Grid Voltage Range180V-280V
Protection DegreeIP65
Operating Temperature Range-25~+60°C
Cooling MethodNatural Convection