.52. .53.
10. Specifications10. Specifications
3/N/PE, 220/380, 230/400
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated grid output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
Model
1100
4/8
0.8leading~0.8lagging
50/60
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
600
37500
37500
37500
57.0/54.1
57.0
THDi (at rated output power)
<3%
Start-up voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
180
S5-GC37.5K
Dimensions (W*H*D)
Weight
647*629*252mm
37kg
Max.efficiency
EU efficiency
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Cooling concept
Max.operation altitude
AC connection
Grid connection standard
DC connection
98.7%
98.3%
Transformerless
1W
-25~+60
0~100%
Intelligent redundant fan-cooling
4000m
Display
Communication connections
Warranty
MC4 connector
OT Terminal
LCD, 2×20 Z
RS485, Optional: Wifi, GPRS,USB*
5 years (extand to 20 years)
G98 or G99, VDE-AR-N 4105 / VDE V 0124,
EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1, TOR,
EIFS 2018.2, IEC 62116, IEC 61727, IEC60068,
IEC 61683, EN 50530
Safty/EMC standard
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
200~1000
4*32
4*40
IP66
3/N/PE, 220/380, 230/400
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated grid output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
Model
1100
4/8
0.8leading~0.8lagging
50/60
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
600
40000
44000
44000
60.8/57.7
66.9
THDi (at rated output power)
<3%
Start-up voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
180
S5-GC40K
Dimensions (W*H*D)
Weight
647*629*252mm
37kg
Max.efficiency
EU efficiency
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Cooling concept
Max.operation altitude
AC connection
Grid connection standard
DC connection
98.7%
98.3%
Transformerless
1W
-25~+60
0~100%
Intelligent redundant fan-cooling
4000m
Display
Communication connections
Warranty
MC4 connector
OT Terminal
LCD, 2×20 Z
RS485, Optional: Wifi, GPRS,USB*
5 years (extand to 20 years)
G98 or G99, VDE-AR-N 4105 / VDE V 0124,
EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1, TOR,
EIFS 2018.2, IEC 62116, IEC 61727, IEC60068,
IEC 61683, EN 50530
Safty/EMC standard
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
200~1000
4*32
4*40
IP66
Optional USB* :only for the brazilian market Optional USB* :only for the brazilian market