10. Specifications
.56.
10. Specifications
.57.
Dimensions (W*H*D)
Weight
647*629*252mm
3/PE, 220
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated grid output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
Max.efficiency
EU efficiency
Model
Topology
Self consumption (night)
1100
3/6
0.8leading~0.8lagging
50/60
97.8%
97.3%
Transformerless
<1W
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
600
20000
22000
22000
52.5
57.7
THDi (at rated output power)
<3%
Start-up voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
180
S5-GC20K-LV
200~1000
3*32
3*40
Operating ambient temperature range
Relative humidity
Ingress protection
Cooling concept
Max.operation altitude
AC connection
Grid connection standard
DC connection
-25℃~+60℃
0~100%
Intelligent redundant fan-cooling
4000m
Display
Communication connections
Warranty
MC4 connector
OT Terminal
LCD, 2×20 Z
RS485, Optional: Wifi, GPRS,USB*
5 years (extand to 20 years)
G98 or G99, VDE-AR-N 4105 / VDE V 0124,
EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1, TOR,
EIFS 2018.2, IEC 62116, IEC 61727, IEC60068,
IEC 61683, EN 50530
Safty/EMC standard
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
37kg
IP66
3/PE, 220
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated grid output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
Model
1100
3/6
0.8leading~0.8lagging
50/60
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
600
15000
16500
16500
39.4
43.3
THDi (at rated output power)
<3%
Start-up voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
180
S5-GC15K-LV
Dimensions (W*H*D)
Weight
647*629*252mm
Max.efficiency
EU efficiency
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Cooling concept
Max.operation altitude
Transformerless
<1W
0~100%
4000m
97.8%
97.3%
37kg
-25℃~+60℃
Intelligent redundant fan-cooling
AC connection
Grid connection standard
DC connection
Display
Communication connections
Warranty
MC4 connector
OT Terminal
LCD, 2×20 Z
RS485, Optional: Wifi, GPRS,USB*
5 years (extand to 20 years)
G98 or G99, VDE-AR-N 4105 / VDE V 0124,
EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1, TOR,
EIFS 2018.2, IEC 62116, IEC 61727, IEC60068,
IEC 61683, EN 50530
Safty/EMC standard
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
200~1000
3*32
3*40
IP66
Optional USB* :only for the brazilian market Optional USB* :only for the brazilian market