Important Safety Instructions
SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and
OPERATING INSTRUCTIONS. You will need to refer to it before attempting any
installation or maintenance.
ALWAYS keep these instructions with the unit so that they will be easily accessible.
Failure to read and follow these warnings and instructions could result in property
damage, serious injury, or death.
ALWAYS disconnect the pump from the power source before servicing or making
adjustments.
NEVER handle the pump or motor with wet hands or when standing on a wet or damp
surface while the pump is plugged into the power source.
MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE. This pump is
wired with a 3-prong grounded plug. To reduce the risk of electric shock, be certain
that it is only connected to a properly grounded, 3-prong receptacle. If you have a 2-
prong receptacle, have a licensed electrician replace it with a 3-prong receptacle
according to local codes and ordinances.
NEVER bypass grounding wires or remove the ground prong from the plug.
DO NOT use an extension cord. The electrical outlet should be within the length of the
pump’s power cord, and at least 4 feet above the floor level to minimize potential
hazards from flood conditions.
DO protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals.
Avoid kinking the cord.
MAKE SURE the supply circuit has a dedicated fuse or circuit breaker rated to handle
the power requirements noted on the nameplate of the pump.
DO NOT use the power cord or strain relief to carry the pump. Use the pump handle.
DO NOT pull on the float switch cord.
DO NOT operate the pump or control unit if it has been damaged in any way.
DO NOT use sump pumps in pits handling raw sewage, salt water, or hazardous liquids.
This pump is for ground water use only.
DO NOT use in continuous duty applications such as fountain ponds. This pump is rated
for intermittent use only.
DO NOT disassemble the pump or float switch. When service is required, contact
Glentronics technical support at 800-991-0466, option 3. Return the product to the
manufacturer for any repairs at the following address:
Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069
When installing or replacing a primary sump pump you should also install a battery
backup sump pump system.
Risk of electric shock. To reduce this risk, observe the
following precautions.
To reduce the risk of hazards that can cause injury or
property damage, observe the following precautions.
Cast Iron Sump Pumps
Instruction Manual &
Safety Warnings
Items Included:
Pump with vertical float switch
You may also need:
A 1-1/2” PVC pipe adapter to screw into the discharge hole on top of the pump
1-1/2” rigid PVC pipe to connect to the existing plumbing
A check valve or rubber union
PVC pipe cleaner and cement
Wire ties or hose clamps
Model CIS-33V & CIS-50V
!
WARNING
!
CAUTION
Specifications 1/3 HP Model CIS-33V 1/2 HP Model CIS-50V
GPH @ 0’ 4000 4300
GPH @ 10’ 3200 3840
Pump diameter 9.5” 9.5”
Volts 115V, 60Hz 115V, 60Hz
Amps 5.0 5.5
Question and Answer IconNeed help?

Do you have a question about the Glentronics Cast Iron CIS-33V and is the answer not in the manual?

Summary

Safety Warnings and Instructions

General Safety Instructions

Essential safety guidelines and warnings to prevent property damage and injury.

Electrical Shock Prevention

Precautions to reduce the risk of electric shock during operation and servicing.

Hazardous Operation Precautions

Guidelines to reduce injury or property damage risks during pump use.

Product Specifications

Installation and Operation

Installation Steps

Detailed instructions for proper pump installation and pit preparation.

Connecting the Pump

Guidance on properly connecting the pump to the power source.

Completing the Installation

Final checks and procedures after pump installation.

Vertical Float Switch Operation

Explanation of how the vertical float switch controls pump activation and deactivation.

Maintenance and Troubleshooting

Maintenance Checklist

Recommended periodic checks to ensure optimal pump performance and longevity.

Backup Pump Installation

Information on installing a battery backup system for power outages.

Troubleshooting Guide

Solutions for common pump operational issues and problems.

Limited Warranty Information

Warranty Coverage Details

Specifies what parts and labor are covered under the warranty.

Warranty Exclusions

Lists conditions and situations not covered by the product warranty.

Obtaining Warranty Service

Instructions on how to get service and contact the manufacturer.

Summary

Safety Warnings and Instructions

General Safety Instructions

Essential safety guidelines and warnings to prevent property damage and injury.

Electrical Shock Prevention

Precautions to reduce the risk of electric shock during operation and servicing.

Hazardous Operation Precautions

Guidelines to reduce injury or property damage risks during pump use.

Product Specifications

Installation and Operation

Installation Steps

Detailed instructions for proper pump installation and pit preparation.

Connecting the Pump

Guidance on properly connecting the pump to the power source.

Completing the Installation

Final checks and procedures after pump installation.

Vertical Float Switch Operation

Explanation of how the vertical float switch controls pump activation and deactivation.

Maintenance and Troubleshooting

Maintenance Checklist

Recommended periodic checks to ensure optimal pump performance and longevity.

Backup Pump Installation

Information on installing a battery backup system for power outages.

Troubleshooting Guide

Solutions for common pump operational issues and problems.

Limited Warranty Information

Warranty Coverage Details

Specifies what parts and labor are covered under the warranty.

Warranty Exclusions

Lists conditions and situations not covered by the product warranty.

Obtaining Warranty Service

Instructions on how to get service and contact the manufacturer.

Glentronics Cast Iron CIS-33V Specifications

General IconGeneral
TypeSump Pump
ModelCIS-33V
Horsepower1/3 HP
Voltage115V
Maximum Flow Rate3000 GPH
Switch TypeVertical Float Switch
MaterialCast Iron
Maximum Head25 ft
Discharge Size1-1/2 in