23
4000123942-2
10a Horizontal Top Flue Installation
10a.1 The Horizontal Top flue - kit 86285H
Is suitable for installations that require a max. flue length "L" of
740mm.
If a shorter flue length is required, the flue can be cut to a min.
length"L" of 260mm rear or 300mm side. See diagram 10a.2 for
min. flue lengths.
Note: Additional 1 metre extensions, 90° and 45° bends are
available. The maximum extended flue is 3.5m. The use of flue
bends requires the maximum extended flue lengths to be
reduced by 1m. for 90° and 0.5m. for 45°.
10a.2 Flue systems rear and side, refer to
diagram 10a.1.
10a.3 Flue cutting, refer to diagram 10a.2.
Important: Do not leave any burrs or sharp edges on the cut
ends of the pipes.
11886
Diagram 10a.2
70mm
65mm
410 mm
Max. Flue length 660mm
Min. Flue length 425mm
205mm
20mm
Min. Clearance
75mm
Min. Wall Thickness
70mm
184mm
65mm
Max. Flue length 660mm
Min. Flue length 425mm
75mm
Min. Wall Thickness
SIDE FLUE
REAR FLUE
L
L
Note :
Top of boiler
casing not
front panel
Note :
Top of boiler
casing not
front panel
* refer to diagram 6.1
11646
B
C
J
I
H
F
G
A
D
The flue kit 86285H comprises:
- Air duct pipe .......................................................... A
- Flue duct pipe ........................................................B
- Elbow.......................................................................C
- Fixing collar seal .................................................... D
- Fixing collar..............................................................E
- External rubber sealing collar............................... F
- Internal flange .......................................................G
- Gasket..................................................................... H
- Screws .......................................................................I
- 'O' rings..................................................................... J
Diagram 10a.1
E
Horizontal Top flue kit

Related product manuals