0020092785_02 - 05/10 - Glow-worm
- 12 -
7.4 Mounting
Make sure that the equipment used for implementing the
installation is compatible with that of the appliance.
Determine the assembly location. See the "Appliance
location" chapter.
735
709
63***
160
160
=246=
170
Ø105**
Ø125*
123
123
* 80/125ue►Ø150mm
** 80/125ue►Ø130mm
*** 80/125ue►156mm
Take the wall template and place in the desired position
on the wall, giving due consideration to the required boiler
clearances, see chapter "Appliance location ► Clearances",
and the ue you are tting.
7.4.1 Fixingtothewall
130
90°
4
5
6
2
1
3
Key
1 Wall template
2 Standarduelengthhorizontal
3 2.5°44mm/metreinclinedextendeduelength
4 Wall plug
5 Hanging bracket
6 Screw(notsupplied)
Flue hole cutting
Mark the position of the ue centre.
Remove the wall template, then drilling the ue hole.
i
The ue is designed with an internal fall of 44mm/
metre (2.5º), therefore the hole can be drilled
horizontally.
Use a 105mm diameter core drill for external access ue
installation (60/100 ue) (80/125 ue ► Ø130mm).
Use a 125mm diameter core drill for internal access only ue
installation (60/100 ue) (80/125 ue ► Ø150mm).
i
If ue extension pipes are to be used then a core
drill size of 125mm is required. This will allow the
extension pieces to slope at 44mm/metre (2.5º)
towards the boiler.
If tting a side ue, extend the ue centre line into the corner
then 130mm along the adjacent wall.
If tting an extended side ue, determine the ue hole centre
by extending the dashed inclined line on the template to the
side wall. This dashed line is drawn at 44mm/metre (2.5º)
rise from the boiler. Where this line reaches the side wall, a
horizontal line should be marked. The vertical centre line of
the ue should then be marked at 130mm from the back wall.
To allow for the ue passing through the wall at this angle
a 125mm hole should be drilled irrespective of internal or
external installation.
Hanging bracket xing
Due to the varied site conditions, xings are not supplied and
advise that the installer should supply those which are suitable.
Drill the holes for the xing screws in accordance with the
wall template.
Fix the hanging bracket on the wall.