18.7 Condensate trap
a
Warning: condensate is mildly acidic. Use
protective gloves.
5
4
3
2
1
1
Key
1 The condensate trap
2 Discharge of condensates
3 Siphon
4 Condensate trap retaining clips
5 Hose
Place a container under the condensate trap (1).
Remove the siphon (3) from he recoverer and clean.
Disconnect the condensation discharge (2).
Disconnect the heat exchanger hose (5).
Remove the condensate trap (1) using the clips (4).
Clean the hose, the trap and the siphon, remove any
accumulated dirt.
Reassemble the components, taking care to position the
gaskets correctly.
Start the siphon (3) and ll with water.