EasyManua.ls Logo

Glow-worm 30sxi - Automatic Air Vent

Glow-worm 30sxi
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
0020092785_02 - 05/10 - Glow-worm
- 45 -
19.3.1 Expansion vessel
B
C
D
E
A
3
2
1
4
2
1
Key
1 Connector
2 Expansion vessel
3 Upper support bracket
4 Retainingscrew
5 Gasket
Drain the boiler heating circuit as described in the
appropriate chapter "Draining".
Remove the two screws (4).
Undo the connector (1) at the base of the vessel.
Remove upper support bracket (3).
Remove the expansion vessel (2).
Fit a new gasket between the expansion vessel and
connector.
Rell, vent and pressurise the boiler.
MAINTENANCE

Table of Contents

Other manuals for Glow-worm 30sxi

Related product manuals