0020127401_00 - 06/11 - Glow-worm
HOW TO USE YOUR APPLIANCE
- 12 -
Filling Loop
Connectthellingloopatthellingtap.
WiththeCentralHeatingowisolation
valveopenasindicatedinthediagram.
Openthecoldwaterinlettap.Slowlyturn
thellingtapuntilthecorrectpressureis
indicatedonthedisplay.
Disconnectthellingloopatthellingtap.
Ifthelossofpressureproblempersists,
youmustcontactyourInstallation/
ServicingcompanyorGlow-wormService.
10 Appliance safety devices
10.1 Boiler Shutdown
Theboilersoftwareisdesignedto
recognisethepotentialforanoverheat
lockoutandwillshutdownbeforethis
happens.
• Torestarttheboiler,pressthereset
button,seechapter"Howtouseyour
appliance►Overview".
Iftheboilerfailstoresumenormal
operationandallexternalcontrolsare
callingforheat,thencallyourInstallation/
ServicingcompanyorGlow-wormservice.
10.2 Protecting against frost
Appliance Protecion
Incaseoftheriskoffrost:
• Makesurethattheelectricalandgas
supplytotheapplianceisturnedon.
• Foranabsenceofseveraldays,you
canleavetheappliancetorunnormally.
Theappliancehasabuiltinfrost
protectiondevicethatprotectstheboiler
fromfreezing.Withthegasandelectric
suppliesONandirrespectiveofanyroom
thermostatsetting,thefrostprotection
devicewilloperatethepumpwhenthe
temperatureoftheboilerwaterfalls
below8
O
C.Atimerisusedsothatthe
temperaturecanbecheckedperiodically.
After10minutesthepumpwillbestopped
ifthetemperatureishigherthan10
O
Cor
hasalreadyreached35
O
C.Theburner
willactivateiftheboilertemperature
doesnotreach10
O
Cafter30minutesor
atanytimeifthetemperaturedropsto
5
O
C.Theburnerwillswitchoffwhenthe
temperaturereaches35
O
C.
Theappliancealwayshasfrostprotection
activewhenthepowerandgassupplyare
on.
System Protection
Theboileralonecannotensurethatthe
installationisprotectedagainstfrost.
NOTE:Anyotherexposedareasofthe
systemshouldbeprotectedbyaseparate
frostthermostat.
Incaseofprolongedabsence,where
powertothedwellingandtheboileris
switchedoff,contactyourInstallation/
ServicingcompanyorGlow-wormService
tohavetheinstallationdrainedortohave
theheatingcircuitprotectedbyaddingan
anti-freezespeciallydesignedforheating
systems.
CAUTION: Your domestic
water circuit (hot and cold) is
not protected by the boiler.
10.3 Condensate Drain Blockage
Asasafetyfeaturetheboilerwillstop
workingifthecondensatedrainbecomes
blocked.Duringfreezingconditionsthis
maybeduetotheformingoficeinthe
condensedrainexternaltothehouse.
• Releaseaniceblockagebytheuseof
warmclothsonthepipe.
Theboilershouldthenrestart.