0020117819_01 - 05/11 - Glow-worm
- 31 -
15.2.5 After-sales service parameters
This menu lets you make adjustments to the following functions
according to the appliances connected, and reset all these
parameters.
Press simultaneously on button (
) and ( ) for 3 seconds.
The parameter number is displayed and its value blinks.
Press the button (M) to access the parameter. The value of the
parameter ashes.
Press the buttons (
) to modify the value.
Press the button (M) to con rm the parameter setting.
Press the buttons ( ) to move to the next parameter.
Perform the previous operations again for the other
parameters.
Press the button (OK) to exit the menu and validate the
settings.
Code Function Description
Setting
Factory
setting
Modi able
parameter
Min Max
100
Type of system
regulation
1 = Not used
2 = Regulation with system of management by contact
3 = Not used
4 = Not used
5 = Not used
6 = Not used
7 = Not used
17 2 Yes
101
Con guration of the
command unit
0 = Command unit used as con guration tool
1 = Not used
2 = Not used
02 0 Yes
102
Updates to the
command unit
software
This parameter displays the latest update to the software that is made on the
heat pump's command unit.
-- - No
103
Version of the
command unit's
software
This parameter displays the version of the heat pump's command unit software - - - No
104 Test modes
By activating these various test modes, you can trigger special functions on the
appliance.
0 = No test
1 = Force the circulator
2 = Force output between terminals 5 and N (code 147)
3 = Force output between terminals 4 and N (code 106)
4 = Force output between terminals 11 and N (code 108)
5 = Force output between terminals 12 and N (code 156)
6 = Force the 3-way gate
7 = Not used
8 = Not used
09 0 Yes
105
Reset the counter
for the circulator
functioning time
This parameter resets, to zero, the functioning time counter for the heat pump's
circulator.
000
(no)
165
(yes)
000
(no)
Yes
106
Con guration of
the output between
terminal channels 4
and N
Con guration of the booster heating
1 = Command booster heating
2 = Not used
12 1 Yes
107
Humidity rate
threshold
This parameter de nes the humidity rate threshold from which the dehumidi er
is switched on.
20% 100% 50% Yes
108
Con guration of
the output between
terminal channels 11
and N
Con guration of dehumidi er
1 = Not used
2 = Dehumidi er command
12 2 Yes
109
Threshold for protection
against frost
This parameter de nes the temperature level of the installation's water from
which protection against frost is activated. This threshold corresponds to the set
temperature to which you should add 3°C.
0°C 6°C 0°C Yes
110
Reset the counter
for the compressor's
functioning time
This parameter resets, to zero, the functioning time counter for the heat pump's
compressor.
000
(no)
165
(yes)
000
(no)
Yes
111
Status of water ow
detector
This parameter lets you check the state of the water ow detector
1 = Su cient water ow detected
0 = No water ow or insu cient ow
-- - No
INSTALLATION

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm Envirosorb2 7 and is the answer not in the manual?

Glow-worm Envirosorb2 7 Specifications

General IconGeneral
BrandGlow-worm
ModelEnvirosorb2 7
CategoryHeat Pump
LanguageEnglish

Related product manuals