Supplied By www.heating spares.co Tel. 0161 620 6677
34
10 Plume Management Kit
10.13 Plume Management Kit
The Plume Management Kit: Part No. A2044100 (white) or
A2044000 (black) can be used to overcome many site issues.
The Plume Management Kit will fit to the Top Horizontal
Telescopic, Rear Horizontal Telescopic and Standard
Horizontal Flue. This enables the flue products to exhaust
further away from the boiler, thereby reducing the impact of
pluming.
NOTE: The flue air inlet can be sited closer to doors, opening
windows and air bricks, than stated in section 4.2, see
diagram 10.27.
The maximum length of the Plume Management Kit must
NOT exceed 6m with a horizontal concentric
flue length of 2m
max.
For each 90
o
bend or 2 x 45
o
bends the maximum length of
the Plume Management Kit must be reduced by 1m.
For more information contact Glow-worm, refer to page 2.
The Plume Management Kit is supplied with installation
instructions.
Refer to BS5546 or BS6798 for advice on disposal of boiler
condensate.
FLUE
OUTLET
FLUE
PRODUCTS
AIR INLET
PLUME
MANAGEMENT
KIT
25mm. MIN.
AIR BRICK
OPENING
WINDOW
OR DOOR
50mm.
MIN.
IMPORTANT: The flue outlet must
not be positioned within 300mm
from an opening, air brick or
opening windows.
12997
Diagram 10.27