EasyManua.ls Logo

Glow-worm Ultracom 30cxi - Page 62

Glow-worm Ultracom 30cxi
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Supplied By www.heating spares.co Tel. 0161 620 6677
62
15 Replacement of Parts
RETAINING
CLIPS (4 OFF)
MAIN PCB
RETAINING
LUGS
FUSE
Diagram 15.22
13313
USER INTERFACE
BOARD
RETAINING
CLIPS
ELECTRICAL
CONNECTION
13355
15.27 Access User Interface and Main PCB
For access, refer to section 15.1.
Remove control box retaining screw, see diagram 15.21.
Hinge down the control box.
Release the control box cover by carefully pressing the four
retaining latches, see diagram 15.21.
15.28 Main PCB
IMPORTANT: When replacing the board refer to instructions
supplied with the replacement.
For access, refer to section 15.27.
Remove the electrical connections to the PCB.
Ease back the four PCB r
etaining clips and withdraw the PCB
from the retaining lugs, see diagram 15.22.
When refitting the rear panel ensur
e the leads are not
trapped.
15.29 User Interface
IMPORTANT: When replacing the board refer to instructions
supplied with the replacement.
Refer to section 15.27 for access.
Remove main PCB, refer to section 15.28.
Remove electrical connection.
Gently ease back the r
etaining clips, see diagram 15.23.
Withdraw the board.
15.30 Fuse, Main PCB - Control Box
For access, refer to section 15.27.
The fuse is located at top left hand side of the PCB, see
diagram 15.22.
15.31 Control Box
For access, refer to section 15.27.
Remove relevant plugs and connectors, refer to wiring
diagram 14.2.
Withdraw grommets and leads so they are hanging loose.
Unthread the retaining cord and r
emove the control box
by drawing it outwards away from its retaining slots, see
diagram 15.21.
15.32 Inner Casing Panel Seal
For access, refer to section 15.1.
Refer to diagram 13.10.
Remove the inner casing panel.
T
o replace remove the old seal, thoroughly clean the casing
surfaces. Fit the new seal, it is supplied to the correct length.
Refit the inner casing panel.
NOTE
: Ensure the seal is fitted correctly giving an airtight
joint.
Diagram 15.21
Diagram 15.23
RETAINING
SLOTS
SECURING
SCREW
REAR
PANEL
CONTROL
PANEL
RETAINING
CLIPS
13535

Other manuals for Glow-worm Ultracom 30cxi