3.2 MOUNTING REQUIREMENTS
1. TEMPERATURE
Make sure the GP-ISW is installed in a location where the normal air temperature is between
-20°C and 40°C. The cooler the better within this range.
2. MOISTURE
Do not allow water or other uids to come into contact with the GP-ISW. Do not expose to
rain, snow or water.
3. VENTILATION
For optimum Inverter performance the GP-ISW must be installed so the front and rear air vents
are not blocked or obstructed in any way. Do not install the GP-ISW in an area with limited
air ow. Allow as much space around the Inverter as possible, leaving at least 4 inches of
airspace clearance around all ventilation areas.
CAUTION! Equipment Damage. Do not mount the GP-ISW in a zero clearance
compartment. Do not cover the ventilation openings. Overheating and mechanical
failure may occur.
4. FIRE
Install the GP-ISW away from the battery bank, away from any ammable or combustible
material (paper, ammable liquids, gasoline, cloths) that may be ignited by heat, sparks or
ames. Never place the Inverter directly above the battery bank - gases from the batteries will
corrode and damage the Inverter, never allow battery acid to drip onto the unit.
5. ACCESSIBILITY / ORIENTATION
Do not block access to the GP-ISW remote control access port, status LEDs and the On/O󰀨
switch. Allow enough room to access the AC and DC wiring terminals and connections as
they will need to be checked and tightened periodically. The GP-ISW must be installed in one
of the approved mounting orientations detailed on page 20. DO NOT MOUNT VERTICALLY.
6. CLEAN
The GP-ISW should be installed in a location which is clean and limits the introduction of dust,
fumes, insects or rodents which could enter and block the Inverter ventilation openings.
7. PROXIMITY TO BATTERY BANK
The GP-ISW should be located as close to the batteries as possible but not within the same
compartment. The length and size of the DC Cables will a󰀨ect performance. Long DC wires
tend to lose e󰀩ciency and reduce the overall performance of the Inverter/Charger. Use the
DC cables recommended on page 23.
INSTALLATION