Battery and
wiring safety
Observe all safety precautions of the battery
manufacturer when handling or working
around batteries. When charging, batteries
produce hydrogen gas, which is highly
Wiring
connections
Ensure all connections are tight and secure.
Loose connections may generate sparks and
heat. Be sure to check connections one week
after installation to ensure they are still tight.
Work safely
Wear protective eyewear and appropriate
clothing during installation. Use extreme
caution when working with electricity and
when handling and working around batteries.
Observe
correct polarity
Reverse polarity of the battery terminals and
array will cause the controller to give a
warning tone. The controller will not function
unless battery terminals are connected to a
battery with proper polarity. Failure to correct
this fault could damage the controller.
the GP-PWM-
10-FM Amp
current and
max voltage
ratings
The maximum current of the solar system is
the sum of parallel-connected PV module–
rated short circuit Currents (Isc) multiplied by
1.25. The resulting system current is not to
exceed 12.5A. If your solar system exceeds
this value, contact your dealer for a suitable
controller alternative.
Do not exceed
the GP-PWM-
10-FM max
voltage ratings
The maximum voltage of the array is the sum
of the PV module–rated open-circuit voltage of
the series connected modules multiplied by
1.25 (or by a value from NEC 690.7 provided
in Table 690.7 A). The resulting voltage is not
to exceed 35V. If your solar system exceeds
this value, contact your dealer for a suitable