3.6.6 AC WIRING 1 - Single Phase, ≤30A Service, Single IN/Single OUT [No Sub Panel]
INSTALLATION
IN 1
AC Hot 1 from shore or gen
shore or gen
ACN-IN
AC Neutral from
main panel
AC Ground
AC Ground from shore or gen
Input
Breaker
Wire
Inverter
Pass
Through
3600W
30A @ 120VAC
Single Phase - ≤30 Amp Service
≤30 Amps - 120VAC
#10 AWG
#10 AWG
Generator Power
120/240 VAC
Transfer Switch
(only required if using
a hardwired generator
Transfer Switch
(only required if using
a hardwired generator
Inverter/Charger
Notes:
* All previous converter/charger wiring must be disconnected from the
breaker panel. The IC Series is now used for battery bank charging.
30A
Maximum 30A Break
(single pole)
IN 2
AC Hot 2 from
OUT 2
AC Live to
main panel
main panel
main panel
main panel
shore or gen
shore or gen