OPERATION
4.7 BATTERY TEMPERATURE SENSOR (BTS) OPERATION
The IC Series Inverter/Charger is delivered with a battery temperature sensor. By installing this sensor, the charge voltages are
automatically adapted for deviating temperature. With a BTS installed, if the temperature around the BTS is below 20°C, the absorb and
oatchargevoltageincreases.IfthetemperaturearoundtheBTSisabove20°C,theabsorbandoatchargevoltagedecreases.The
graph below details how much the charge voltage changes (increases or decreases) depending on the temperature reading of the BTS.
4.8 FACTORY DEFAULT VALUES
The IC Series Inverter/Charger uses default values for the following adjustable settings:
Adjustable Settings Default Values
Shore Input 30 Amps (AC)
Low Battery Cut Out 10.5 VDC
VAC Dropout 85 VAC
Max Charge Time 12 Hours
Battery Type AGM 1
Charge Rate 80%
ABS Charge Time 2 Hours
These settings are only adjustable with the GP-ICR-50 remote, which can be purchased separately from Go Power!. For detailed
information on these settings please refer to the remote control manual. The remote also displays the real time Inverter/Charger’s
operatingstatusandallowstheusertoruntheequalizechargingproleonthebatterybank.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Go Power IC Series and is the answer not in the manual?

Go Power IC Series Specifications

General IconGeneral
Output Voltage12 VDC
Battery TypesAGM, Gel, Flooded, Lithium
Protection FeaturesOver-voltage, Over-temperature
Operating Temperature-4°F ~ 140°F (-20°C ~ 60°C)
DimensionsVaries by model
WeightVaries by model