NOISE LEVEL MEASUREMENTS OF
CURTIS DYNA-FOG AEROSOL APPLICATORS
MODEL 63HZ 125HZ
LINEAR SOUND PRESSURE
500HZ 1KHz 2KHz
LEVEL
4KHz
8KHz
OVERALL
WEIGHTED
db (A)
OVERALL
LINEAR
SOUND
PRESSURE
C€ (FRENCH)
MEASURE-
MENT
METHOD
HURRICANE 45 51 59 54 61 64 67 76 77 85
CYCLONE 45 53 53 54 67 62 68 76 76 90
TRAILBLAZER 74 82 86 79 82 78 70 90 97 103
GOLDEN EAGLE 75 87 91 83 78 81 71 92 97
BLACKHAWK 90 88 84 77 68 68 60 92 100
MISTER III 85 83 86 78 70 75 76 90 95
MISTERMAX 89 89 89 85 82 83 81 96 102
NIGHTHAWK 45 51 53 50 45 45 50 61 64
TYPHOON 1
99
**TYPHOON 2 73 73 73 76 76 73 79 90 93
**MAXI-PRO 68 77 74 74 74 74 83 96 99
TORNADO 45 53 53 54 67 62 68 76 76 90
TEST DATE: FEBRUARY 3, 1993
TEST CONDITIONS AND PROCEDURES USED: To simulate an operator's position during normal use, all noise
measurements were taken at a distance of 2.5 feet (.76 meters) from the machines.
Indoor tests were performed in a laboratory of 48 x 33 x 10 feet (14.6 x 10.1 x 3.0 meters) at an ambient air temperature of
70° F (21 °C).
**These tests were taken outdoors and performed with an ambient air temperature of 40° F (4° C).
EQUIPMENT USED: 1.) CERTIFIED GOLDLINE DIGITAL REAL-TIME ANALYZER, MODEL 30.
2.) CERTIFIED GENERAL RADIO SOUND-LEVEL-METER, MODEL 1565-B.
48