IMO83B1 – April 2011
10
6. TECHNICAL INSTRUCTIONS Cont’d
PILOTS
Polidoro 509. Gas to pilot is controlled through an injector spud. This spud
needs to be replaced when converting between L.P. and N.G. If appliance
cannot be correctly adjusted, advise the local gas authority or the appliance
manufacturer.
CONTROLS
The only controls are the PEL 21S gas valves. All are accessible after the front
stainless steel fascia is removed.. If controls get hard to turn, get a service man
to remove the two screws at the front of the control and put a high temperature
graphite grease on the shaft.