IMO83B1 – April 2011
6
3. COMMISSIONING INSTRUCTIONS
OPERATION
(FOR AUTHORISED TECHNICIANS ONLY)
Note: All the appliances that leave our factory have been tested and
adjusted according to the specifications for the required gas. The regulator
may have to be adjusted to achieve the required gas pressure
Note: Before igniting the Teppanyaki plate, remove the protective coating
on the plate with solvent (e.g. mentholated spirits).
Ensure that the pressure at the pressure test point on the manifold is as per the
rating plate. If the pressure is not the same use a screwdriver to adjust the
pressure regulator (turning screw clockwise will increase the pressure).
Turn the control knob to low and check that the flame size has decreased
substantially. If flame has not decreased, then using a small flat headed
screwdriver adjust the “min gas screw” on the front of the gas control until the
min flame gets to desired size (turning screw clockwise will decrease the flame
size).
Turn the Teppanyaki plate off and apply a coating of cooking oil to the whole
griddle plate surface. Failure to do this will cause the warranty to be void.
NOTICE
PLEASE RETURN YOUR WARRANTY CARD
FAILURE TO DO SO WILL VOID
WARRANTY ON THE EQUIPMENT