IM067B2 – June 2010
11
7. TECHNICAL DATA
GAS CONSUMPTION AND INJECTOR SIZES
NG LPG
Mm Drill Mj Mm Drill Mj
2.60 38 60 1.70 51 65
TTP TTP
KPA KPA
0.92 2.60
GAS CONTROL - SPECIFICATION
S.I.T. 830 Tandem
- Thermoelectric flame failure device
- Low rate ignition regulator
- Servo system pressure regulator
- Ignition restart interlock
- Inlet-outlet pressure test point
Illustrated on Page 12 & 13
CONVERSION TO L.P. GAS
1. Disconnect oven from gas/electrical supply.
2. Install LPG governor as per AGA Code AS4563/AG300.
3. Change burner injector as per table.
4. Connect gas and electrical supply.
5. Start oven to see burner flame.
6. Set T.P.P. as per table.
7. Step through installation/commissioning instructions.