IM067B2 – June 2010
7
3. COMMISSIONING INSTRUCTIONS
COMMISSIONING CHECK LIST
1. CHECK FOR DAMAGE AND MISSING PARTS.
2. REMOVE ALL PLASTIC COATING FROM S/STEEL PANELS.
3. MAKE SURE ALL PARTS ARE IN THEIR CORRECT POSITION E.G. TRAYS
BURNERS KNOBS.
4. MAKE SURE ALL GAS CONNECTIONS ARE CORRECT AND TIGHT.
5. LEVEL OFF UNIT LEFT TO RIGHT AND ALSO MAKE SURE THAT FRONT IS
JUST 3-4 MM LOWER TO ALLOW FOR FLUING.
6. TURN ON GAS .
7. ADJUST GAS PRESSURE WITH THREE-QUARTERS OF THE UNIT
RUNNING, ADJUST GAS PRESSURE.
NATURAL GAS 1.00 KPA ) as per pressure shown
LPG 2.60 KPA ) on Rating Plate
8. TURN ON ONE AT A TIME TO MAKE SURE ALL IS WORKING E.G. BURNER,
RADIANT, GRIDDLE AND STEAMER.
9. SHOW CUSTOMER
A) HOW TO WORK EQUIPMENT
B) HOW TO CLEAN
C) HOW TO PULL IT APART E.G. TRAYS, TRIVETS.
D) ALSO WHAT NOT TO DO, E.G. GREASE AND OIL IN CONTROLS.
10. CHECK TO MAKE SURE MANUALS AND WARRANTY CARDS ARE THERE.
ALSO GO THROUGH MANUAL WITH CUSTOMER E.G. LIGHTING,
CLEANING.
NOTE
HOSES SHOULD NEVER BE USED ON THE APPLIANCE.
USE OF HOSES WILL VOID WARRANTY
“DO NOT SPRAY AEROSOLS IN VICINITY OF APPLIANCE WHILST
OPERATING”